User's Manual

Electrical Specifications DTS-800 Reference Manual Application Information
01-DTS800 CDK-1 X1 AnyDATA.NET Proprietary Use Subject to
Restrictions 19
4.2 Timing characteristics
4.2.1 External CODEC Timing
External PCM CODEC to Modem timing
Modem to External PCM CODEC timing
PARAMETER DESCRIPTION MIN TYP. MAX UNIT
t
clk
PCM-CLK cycle time 400 500 ns
t
clkl
PCM-CLK low time 200 250 ns
t
clkh
PCM-CLK high time 200 250 ns
t
su(sync)
PCM_SYNC setup time to PCM_CLK falling 150 ns
t
h(sync)
PCM_SYNC hold time after PCM_CLK falling 350 ns
t
su(din)
PCM_DIN setup time to PCM_CLK falling 50 ns
t
h(din)
PCM_DIN hold time after PCM_CLK falling 10 ns
t
pdout
Delay from PCM_CLK falling to PCM_DOUT 50 ns
External PCM CODEC Parameters
t
clk
t
clkl
t
clkh
t
su(sync)
t
h(sync)
t
su(din)
t
h(din)
MSB
LSB
PCM _CLK
PCM _SYNC
PCM _DIN
t
clk
t
clkl
t
clkh
t
su(sync)
t
h(sync)
MSB LSB
PCM _C LK
PCM _SYN C
PCM_DOUT
t
pdout
t
pdout
t
zdout