ComCf Screen: This screen is used to configure the TX maximum operating
thresholds to engage safety and protective power reduction and shutdown
mechanisms.
FwdMax: Max TX Forward Power fault threshold
ReflMax: Max TX Reverse Power fault threshold
Rejt1-7Max: Max TX Reject Load fault threshold
VSWRMax: Max TX VSWR fault threshold
(Note: Press the word FwdMax, ReflMax, etc. to see a pop-up screen to
modify these settings. Warning changing these settings may cause
improper TX operation, damage, and shutdown of the Transmitter
System).
FwdPara: Adjust to calibrate the main screen FWD Power Metering
ReflPara: Adjust to calibrate the main screen Refl Power Metering