User's Manual

MHPTV TX User Manual
MHPTV-USR-DOC-V3.0, 10/18/2019 Page 63 of 148
Rear Panel
The rear panel of Control Unit is shown below:
RF_OUT-1/…/RF_OUT-8
Connector: SMA
Impedance: 50 Ω
Note: Sends pre-amplified RF signal to the inputs of PA modules
RF_IN_A/RF_IN_B
Connector: SMA
Impedance: 50 Ω
Note: To receive the RF_OUT signal from Exciter_A / Exciter_B
ERS485-A/ERS485-B: To be connected to REMOTE of Exciter_A/Exciter_B for
internal communication between exciters and Control Unit.
CAN-1A: To be connected to CAN port of the power detection board.
CAN-1B/2A/2B: Reserved.
RS-485: To be connected in series with RS485 ports of all PA modules.
LAN: 10M/100M Ethernet port for web-based remote control (IP address:
192.168.1.210)
AC INPUT/FUSE: 90-240 VAC
Power Switch: ON/OFF