4.2 RAISE/LOWER POWER
Local Control: To raise or lower the TX system forward power, please adjust the
target AGC power setting on the Controller AGC screen. Monitor the change in
power via the Home screen FWD Power meter (which may take up to 60
seconds). Please note, as an alternative, you could disable the Controller AGC
(Turn AGC Off) and raise/lower the Exciter output drive.
Remote Control: To raise or lower the TX system forward power from the
Controller Web Interface, please adjust the target AGC power setting and press
the SET button to the right (network to the Controller module via rear panel RJ-
45 LAN connection, default IP address 192.168.1.210). Please note, as an
alternative, you could disable the Controller AGC (AGC-Status = Off) and
raise/lower the Exciter output drive.
Set Target AGC to
desired System
Forward Power
Set Target AGC to
desired System
Forward Power