User's Manual

MHPTV TX User Manual
MHPTV-USR-DOC-V3.0, 10/18/2019 Page 92 of 148
Normal operation for the MHPTV TX is to run with the Transmitter AGC enabled
to compensate for slight variations in output power due to changes in
temperature, AC mains, etc. It is not recommended to perform power meter
calibration with AGC enabled.
1. Please navigate to the Controller AGC screen (by pressing the CONFIG
button and then AGC button) and disable AGC by pressing the Green button
(as shown below), so that the button then becomes transparent (blue). This
indicates that AGC is OFF.
2. Adjust the Exciter POWER setting under the RF submenu to achieve the
desired Forward System Power (1000W for example) as monitored on the
Controller Home screen.
Press AGC button
to turn AGC OFF
(button becomes
transparent = blue)
System FWD
power meter