User's Manual

MHPTV TX User Manual
MHPTV-USR-DOC-V3.0, 10/18/2019 Page 96 of 148
8. Please note: the above FWD power meter calibration (and below Reflected
and Reject meter readings) may alternatively be adjusted and calibrated via
the Controller Web interface (192.168.1.210) Common-Set Tab instead of the
Controller front panel touchscreen as shown below.
9. Repeat steps 3 through 7 above, this time removing, measuring, and returning
the REFL IN sample to calibrate the Reflected system power meter by
adjusting the value of RefPara below.
Calibration for
FWD power
meter (FwdPara)
Calibration for
FWD power meter
(FWD-Para)