Normal Operaon
Owner's Guide
TEMPERATURE SETTINGS ON THE PCB
-WITHOUT REMOTE CONTROLLER-
There are four temperatures that you can select by changing the DIP switch settings on the computer
board. See the table below.
Location of the bank of DIP switches on the computer board
110 and 310 models
Temperatures settings
113 °F (45 °C)
122 °F (50 °C)
Default
131 °F (55 °C) 140 °F (60 °C)
ON
87654321
ON
87654321
ON
87654321
ON
87654321
510 model
Temperatures settings <Right bank of DIP switches>
104 °F (40 °C) 113 °F (45 °C)
122 °F (50 °C)
Default
140 °F (60 °C)
ON
654321
ON
654321
ON
654321
ON
654321
NOTE: The dark squares indicate the correct DIP switch positions.
WARNING
 DO NOT adjust any other DIP switches other than the ones that are indicated below.
 Turn off the power supply to the water heater before changing the DIP switch
settings.
 Failure to observe these warnings could result in carbon monoxide poisoning, severe
personal injury, or death.
FLOW
110 / 310 Computer board
DIP switches
510 Computer board
DIP switches
(Right bank)
Appliance/Use
Flow rate GPM
Lavatory Faucet 1.0 (3.8 L)
Bath Tub
4.0 – 10.0
(15.1 - 37.9 L)
Shower 2.0 (7.6 L)
 1.5 (5.7 L)
Dishwasher 1.5 (5.7 L)
Washing machine 4.0 (15.1 L)
Household Flow Rates
Taken from UPC 2006
 The flow rate through the water heater is limited to a
maximum of 6.6 GPM for the 110 model, 8.0 GPM for the 310
model, and 10.0 GPM for the 510 model.
 The temperature setting, along with the supply temperature
of the water will determine the flow rate output of the unit.
 Please refer to the temperature vs. gallons per minute charts
on p. 56 to determine the likely flow rates based on your local
ground water temperature and your desired outlet water
temperature.
 Refer to the right table for typical household plumbing fixture
flow rates to determine what the water heater can do in a
household application.