User Guide

48 Page
Troubleshoong
Owner's Guide
110 and 310 510
Malfunction
description
Diagnosis
Red
LED
Remote
Remote
7 Seg LED
Two
Flashes
39* 391*
Air-fuel ratio
rod failure
 Check for connection/breakage of wires (Part #709) and/
or soot on the AFR rod (Part #108).
N/A
N/A 441
Flow sensor
failure (Easy-Link
System only)
 Check for connection/breakage of wires and/or debris on
the flow sensor impeller (Part #402, 717).
Six
Flashes
51 510
Abnormal gas
solenoid valve
 Check for connection/breakage of wires (Part #708) and/
or burn marks on the computer board (Part #701).
Six
Flashes
55 N/A
Abnormal main
gas valve
 Check for connection/breakage of wires (Part #708) and/
or burn marks on the computer board (Part #701).
Four
Flashes
61* 611*
Fan motor fault  Check for connection/breakage of wires, dust buildup
in the fan motor (Part #103) and/or burn marks on the
computer board (Part #701).
 Check for frozen/corrosion of connectors (Part #103).
N/A
N/A 651*
Flow adjustment
valve fault (Easy-
Link System only)
 Inspect the flow adjustment valve (Part #402), for
connection/breakage of wires (Part #718), locked motor
drive due to scale buildup, and/or water leakage.
One
Flash
70* 701*
Computer board
fault
 Check for connection/breakage of wires (Part #714) and/
or burn marks on the computer board (Part #701).
 Check the power supply of the water heater.
Six
Flashes
72* 721*
False flame
detection
 For indoor models, check if condensate drain is installed
on the vent collar of the water heater.
 Check if there is leaking from heat exchanger (Part #401).
N/A
74 741
Miscommuni-
cation between
water heater
and remote
controller
 Check the model type of the remote controller.
 Inspect the connections between the water heater and
remote controller.
 Check the power supply of the water heater.
N/A
N/A 761
Miscommuni-
cation in Easy-
Link System
 Check if the connections between the parent unit and the
child units are correct. Refer to pp. 29 and 30.
Five
Flashes
99* 991*
Imperfect
combustion
 Check the gas type of the water heater.
 Inspect the environment around the water heater.
Determine how long the unit has been installed.
 Check the altitude/elevation of the area of where the
water heater is installed.
 Check if there is any blockage in the intake air and/or
exhaust.
 If the water heater is installed as a direct-vent system,
check to make sure that there is enough distance between
the intake air terminal and the exhaust terminal.
 Check if there is grease and/or dirt in the burner (Part
#101) and the fan motor (Part #104), especially if the
water heater has been installed in a contaminated area.
*These error codes will be cleared when water flow stops.