User Guide
48 Page
Troubleshoong
Owner's Guide
110 and 310 510
Malfunction
description
Diagnosis
Red
LED
Remote
Remote
7 Seg LED
Two
Flashes
39* 391*
Air-fuel ratio
rod failure
Check for connection/breakage of wires (Part #709) and/
or soot on the AFR rod (Part #108).
N/A
N/A 441
Flow sensor
failure (Easy-Link
System only)
Check for connection/breakage of wires and/or debris on
the flow sensor impeller (Part #402, 717).
Six
Flashes
51 510
Abnormal gas
solenoid valve
Check for connection/breakage of wires (Part #708) and/
or burn marks on the computer board (Part #701).
Six
Flashes
55 N/A
Abnormal main
gas valve
Check for connection/breakage of wires (Part #708) and/
or burn marks on the computer board (Part #701).
Four
Flashes
61* 611*
Fan motor fault Check for connection/breakage of wires, dust buildup
in the fan motor (Part #103) and/or burn marks on the
computer board (Part #701).
Check for frozen/corrosion of connectors (Part #103).
N/A
N/A 651*
Flow adjustment
valve fault (Easy-
Link System only)
Inspect the flow adjustment valve (Part #402), for
connection/breakage of wires (Part #718), locked motor
drive due to scale buildup, and/or water leakage.
One
Flash
70* 701*
Computer board
fault
Check for connection/breakage of wires (Part #714) and/
or burn marks on the computer board (Part #701).
Check the power supply of the water heater.
Six
Flashes
72* 721*
False flame
detection
For indoor models, check if condensate drain is installed
on the vent collar of the water heater.
Check if there is leaking from heat exchanger (Part #401).
N/A
74 741
Miscommuni-
cation between
water heater
and remote
controller
Check the model type of the remote controller.
Inspect the connections between the water heater and
remote controller.
Check the power supply of the water heater.
N/A
N/A 761
Miscommuni-
cation in Easy-
Link System
Check if the connections between the parent unit and the
child units are correct. Refer to pp. 29 and 30.
Five
Flashes
99* 991*
Imperfect
combustion
Check the gas type of the water heater.
Inspect the environment around the water heater.
Determine how long the unit has been installed.
Check the altitude/elevation of the area of where the
water heater is installed.
Check if there is any blockage in the intake air and/or
exhaust.
If the water heater is installed as a direct-vent system,
check to make sure that there is enough distance between
the intake air terminal and the exhaust terminal.
Check if there is grease and/or dirt in the burner (Part
#101) and the fan motor (Part #104), especially if the
water heater has been installed in a contaminated area.
*These error codes will be cleared when water flow stops.