Brochure

Specifications
7-7/8" (199 mm)
GAS 5-1/8" (131 mm)
COLD 6-3/4" (172 mm)
HOT 5-1/2" (140 mm)
7-1/2" (189 mm)
GAS 5-7/8" (147 mm)
Condensate drain port
COLD 5/8" (17 mm)
HOT 4-3/4" (120 mm)
17-5/8" (448 mm)
6-1/4" (159 mm)
5-3/4" (147 mm)
120 VAC 3" (77 mm)
120 VAC 6-7/8" (174 mm)
Drain port
Female
10-3/4" (272mm)
22-1/22" (570 mm)
Condensate drain port
4" (102 mm)
2-5/8" (68 mm)
Exhaust
Intake
Female
7-7/8" (199 mm)
7-1/2" (189 mm)
7" (180 mm)
4" (101 mm)
17-3/4" (450 mm)
HOT 4-3/4" (120 mm)
6-3/4" (170 mm)
COLD 5/8" (17 mm)
GAS 5-3/4" (147 mm)
Condensate drain port
23-5/8" (600 mm)
2-5/8" (65 mm)
5-3/4" (147 mm)
11-1/4" (285 mm)
1/2 (13 mm)
GAS 5-1/8" (131 mm)
HOT 5-1/2" (140 mm)
COLD 6-3/4" (172 mm)
Condensate drain port
6-1/4" (159mm)
4" (102 mm)
24-7/8" (631 mm)
120 VAC 3" (77 mm)
Drain port 6" (152 mm)
120 VAC 6-7/8" (174 mm)
7-7/8" (199 mm)
GAS 5-1/8" (131 mm)
COLD 6-3/4" (172 mm)
HOT 5-1/2" (140 mm)
7-1/2" (189 mm)
GAS 5-7/8" (147 mm)
Condensate drain port
COLD 5/8" (17 mm)
HOT 4-3/4" (120 mm)
17-5/8" (448 mm)
6-1/4" (159 mm)
5-3/4" (147 mm)
120 VAC 3" (77 mm)
120 VAC 6-7/8" (174 mm)
Drain port
Female
10-3/4" (272mm)
22-1/22" (570 mm)
Condensate drain port
4" (102 mm)
2-5/8" (68 mm)
Exhaust
Intake
Female
7-7/8" (199 mm)
7-1/2" (189 mm)
7" (180 mm)
4" (101 mm)
17-3/4" (450 mm)
HOT 4-3/4" (120 mm)
6-3/4" (170 mm)
COLD 5/8" (17 mm)
GAS 5-3/4" (147 mm)
Condensate drain port
23-5/8" (600 mm)
2-5/8" (65 mm)
5-3/4" (147 mm)
11-1/4" (285 mm)
1/2 (13 mm)
GAS 5-1/8" (131 mm)
HOT 5-1/2" (140 mm)
COLD 6-3/4" (172 mm)
Condensate drain port
6-1/4" (159mm)
4" (102 mm)
24-7/8" (631 mm)
120 VAC 3" (77 mm)
Drain port 6" (152 mm)
120 VAC 6-7/8" (174 mm)
0
1
2
3
4
5
6
7
8
9
10
0 20
240H: Flow Rate vs. Temperature Rise
40 60 80 100 120
Temperature Rise (°F)
Flow Rate (gpm)
20
0
40
100
120
60
80
0
5
10
15
20
25
30
35
40
45
50
0.0 1.0
240H: Pressure Loss
2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Pressure Loss (psi)
Head (ft)
Flow Rate (gpm)
Indoor and Outdoor Installation Options
Power Vent or Power Direct Vent Design
Ultra-Low NOx Emissions
Flow Rate up to 6.6 GPM
Values based on factory testing. 0.4 GPM required for
continuous fire after initial ignition
Water Pressure: 15-150 psi
Pressure Only Relief Valve Requires (Min 160,000 btu/h,
150 psi).
40 psi or above recommended for max. flow
Warranty
15-year limited warranty on heat exchanger in residential
applications.
5-year limited warranty on heat exchanger in commercial
applications.
5-year warranty on all parts.
Refer to hotwater.com for further warranty details
Dimensions
32