Table Of Contents
- Safe Installation, Use and Service
- APPROVALS
- General Safety Information
- Introduction
- Features And Components
- Installation Considerations
- Installation Requirements
- Gas Supply Systems
- Supply Gas Regulator
- Power Supply
- Mixing Valves
- Dishwashing Machines
- Closed Water Systems
- Thermal Expansion
- Temperature-Pressure Relief Valve
- Condensate Drain
- Combustible Material Storage
- Contaminated Air
- Air Requirements
- Unconfined Space
- Confined Space
- Fresh Air Openings For Confined Spaces
- Outdoor Air Through Two Openings
- Outdoor Air Through One Opening
- Outdoor Air Through Two Horizontal Ducts
- Outdoor Air Through Two Vertical Ducts
- Air From Other Indoor Spaces
- Installation Requirements - Commonwealth of Massachusetts
- Venting Installation
- General Venting Information
- General Venting Instructions
- Intake Air Connection
- Venting Requirements
- Venting Installation Sequence
- Power Vent Installation
- Direct Vent Installation
- Vertical Termination Installation
- Sidewall Termination Installation
- Polypropylene Installations
- Al29-4C® Vent Installations
- Concentric Termination Installation
- 4 Inch Concentric Termination Installation
- Low Profile Vent installation
- Venting Arrangements
- Termination Clearances Sidewall Power Vent
- Termination Clearances Sidewall Direct Vent
- Water Heater Installation
- Temperature Regulation
- Control System Operation
- Start Up
- Troubleshooting
- Maintenance
- Diagrams
- notes
- notes
- notes
- Service Inquiries:
- Commercial
- Water Heater
- Limited Warranty
29
The water heaters covered by this manual are approved to
be installed using the approved vent terminations shown
in this manual. This means that, the installer must use the
adapter listed in Tables 9 and 10 and a short piece of PVC
pipe to complete the end of the vent system with an approved
termination. In Canada, the PVC pipe length must be listed
to ULC636.
AL29-4C
®
VENT INSTALLATIONS
(AL29-4C® is a registered trademark of Allegheny Technologies, Inc.)
The water heaters covered by this manual are approved
to be installed with AL29-4C® stainless steel vent material
using parts from the manufacturers listed in Tables 9 and 10
below. These listed systems must be installed using the vent
manufacturer’s instructions including their listed clearances
to combustible and noncombustible materials. Refer to Table
6 on page 23 for the maximum and minimum equivalent
linear vent lengths and number of elbows that may be used.
However, use Tables 9 and 10 below to find the appropriate
equivalent linear vent lengths for the AL29-4C® elbows.
NOTE: The equivalent lengths of the AL29-4C® elbows are
different than those from smooth walled plastic vents. Consult
Tables 9 and 10 for the correct equivalent linear vent lengths.
Listed vent systems composed of AL29-4C® must not mix
parts from the different manufacturers. The joints of these
products are sealed by internal gaskets. Do not use any
other type of sealant. When assembling these vent systems,
follow the vent manufacturer’s instructions for cleaning and
lubricating the joints, if required. Each section must be locked
together using the method supplied by the vent manufacturer.
TABLE 9
HeatFab Saf-T Vent AL29-4C
®
Vent System Parts
Diameter
Flue Outlet
Adapter
*Straight Pipe
(3’ Section)
45° Elbow
Equivalent
Linear Length,
45° Elbow
90° Elbow
Equivalent
Linear length,
90° Elbow
Adapter to
PVC
3 inches 9301 PVC 9307 9311 5 feet 9314 10 feet 9353CPVC
4 inches 9401 PVC 9407 9411 5 feet 9414 10 feet 9454CPVC
*Consult vent manufacturer’s catalog for other available lengths.
TABLE 10
Duravent FasNSeal AL29-4C
®
Vent System Parts
Diameter Flue Outlet Adapter
“Straight Pipe
(3’ Section)
45” Elbow
Equivalent
Linear Length,
45” Elbow
90° elbow
Equivalent
Linear Length,
90- Elbow
Adapter to
PVC
3” 810005378 FSVL3603 FSELB4503 5 feet FSELB9003 10 feet 810009530
4” 810005545 FSVL3604 FSELB4504 5 feet FSELB9004 10 feet 810009529
*Consult vent manufacturer’s catalog for other available lengths.