Product Overview

Page 3 of 4
AOSCE15100
COMMERCIAL
ELECTRIC WATER HEATERS
RECOVERY CAPACITIES
STANDARD kW INPUTS AND AMPERAGE
GPH recoveries at list temperature rise
Standard
kW Input
BTU/
Hour
30°F Rise 40°F Rise 50°F Rise 60°F Rise 70°F Rise 80°F Rise 90°F Rise 100°F Rise 110°F Rise 120°F Rise 130°F Rise 140°F Rise
3 10,239 41 31 24 20 17 15 13 12 11 10 10 9
6 20,478 82 62 49 41 35 31 27 25 22 21 19 18
9 30,717 123 92 74 62 53 46 41 37 34 31 28 26
12.3 41,968 166 125 100 83 71 62 55 50 45 42 38 36
15 51,195 205 154 123 102 88 88 68 61 56 51 47 44
18 61,434 246 184 148 123 105 92 82 74 67 62 57 53
24 81,912 328 246 197 164 140 123 109 98 90 82 76 70
30 102,390 410 308 246 205 176 154 137 123 112 103 95 88
36 122,868 492 369 295 246 211 184 164 148 134 123 113 105
45 153,585 615 461 369 307 263 230 205 184 168 154 142 132
54 184,302 738 554 443 359 316 277 246 221 201 185 170 158
60 204,780 819 615 492 410 351 307 273 246 223 205 189 176
75 255,975 1025 768 615 512 439 384 341 307 279 256 236 219
90 307,170 1229 922 738 615 527 461 410 369 335 307 284 263
* 208V models use one additional immersion heater.
*** Each immersion heater contains three electric elements.
Standard kW
Ratings
Immersion
Heaters***
Wattage
Number of 50A
Contactors
Full Load Current in Amperes
No. of 208V 240V 480V
Single Phase Three Phase
208V 240V 277V 480V 208V 240V 480V
3 1 3,000
1 1
1
14.4 12.5 10.8 6.3 8.3 7.2 3.6
6 1 6,000 28.8 25 21.2 12.5 16.7 14.4 7.2
9 1 9,000 43.3 37.5 32.5 18.8 25 21.7 10.8
12.3 1 12,300 59.1 51.3 44.4 25.6 34.2 29.6 14.8
15 1 15,000 72.1 62.5 54.2 31.3 41.6 36.1 18
18 *1 18,000
2 2
86.5 75 65 37.5 50 43.3 21.7
24 2 12,000 115.4 100 86.6 50 66.6 57.7 28.9
30 2 15,000 144.2 125 108.3 62.5 83.3 72.2 36.1
36 *2 18,000
3 3
2
173.1 150 130 75 99.9 86.6 43.3
45 3 15,000 216.3 187.5 162.5 93.8 124.9 108.3 54.1
54 3 18,000 N/A 225 194.9 112.5 149.9 129.9 65
60 4 15,000 4 4 N/A 250 216.6 125 166.7 145 72
75 5 15,000
5 5 3
N/A N/A N/A 156 208.4 181 90
90 5 18,000 N/A N/A N/A 188 250 217 108