Product Overview

© October 2021 | A. O. Smith Corporation. All rights reserved.
www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
Page 4 of 4
AOSCE15100
COMMERCIAL
ELECTRIC WATER HEATERS
For technical information, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
SPECIFICATION
The heater shall be a glass-lined Custom Xi™ commercial electric model No.______ with _____gallons storage, as manufactured by A. O. Smith. Heater should
be rated at ____kW, ____volts, ____phase, 50/60 cycle AC and constructed in accordance with ASME Code, shall bear appropriate symbol and be listed with
the National Board as required. Heater shall be listed with Underwriters’ Laboratories and classified to The National Sanitation Foundation Standard No. 5. All
internal surfaces of the tank shall be glass-lined with an alkaline borosilicate composition that has been fused-to-steel by firing at a temperature of 1600°F. Tank
shall be cathodically protected with a combination of sacrificial and powered anodes. The entire vessel is to be enclosed in a round steel enclosure with baked
enamel finish. Water heater shall have an electronic control with large LCD displaying current water heater status; provide real time element status and sensing,
low water cutoff and economy mode operation. Shall have 120 volt control circuit transformer, transformer fusing, magnetic contactor(s), element fusing per
N.E.C., and commercial grade Incoloy elements. Temperature controls include limiting switch which will require resetting manually in the event the temperature
reaches 202°F. Foam insulation shall meet the thermal efficiency and/or standby loss requirements of the U. S. Department of Energy and current edition of
ASHRAE/IES 90.1. Heater shall include a CSA Certified and ASME Rated T&P relief valve and a drain valve. Water heater units(s) shall be compatible with building
management systems using Modbus or BACnet with optional ICC interface.
OPTIONAL EQUIPMENT & CONSTRUCTION
HANDHOLE CLEANOUT (NOT AVAILABLE ON 5 & 10 GALLON
MODELS.)
DIAL TYPE COMBINATION TEMPERATURE & PRESSURE GAUGE
(SHIPPED LOOSE)
POWER CIRCUIT FUSING (LESS THAN 120 AMPS)
Sub-divides internal circuitry with maximum of 60 amp fuses. Supplied as
standard when required by NEC and UL.
ALARM HORN
Horns may be furnished to warn of any condition in the heater for which
sensors have been specified.
NORTH CAROLINA CODE - FACTORY INSTALLED T&P VALVE
MODULATING CONTROL
The first element on is the first element off.
Not available on single element, single contactor units.
CONTROL OPTIONS
OPTIONAL INTERNATIONAL VOLTAGES
380, 415, 575 and 600 volts three-phase available with Y connected
elements.