Install Instructions

10 • Residenal Electric Water Heater Use and Care Guide
INSTALLATION
tank to drain, contact a qualied
person.)
Turn the cold water supply
valve OFF.
8
Open the drain valve on the
water heater.
9
Also open a hot water faucet
to help the water in the tank
drain faster.

When the tank is empty,
disconnect the Temperature &
Pressure (T&P) Relief Valve
discharge pipe. You may be able to
reuse the discharge pipe, but do not
reuse the old T&P Relief Valve. A new
T&P Relief Valve comes installed on
your water heater (or on some models,
is in the carton with the water heater).

Disconnect the water pipes.
Many water pipes are
connected by a threaded
union which can be disconnected with
wrenches. If you must cut the water
pipes, cut the pipes close to the water
heater’s inlet and outlet connecons,
leaving the water pipes as long as
possible. If necessary, you can make
them shorter later when you install
the new water heater.

Remove the old water heater.





heater
Completely read all instruc-
ons before beginning. If you
are not sure you can com-
plete the installaon, DO NOT
RETURN THIS UNIT TO THE STORE.
Seek assistance from any of the
following sources:
Professional Installaon is avail-
able for this product and the
work is guaranteed. Call your
local hardware store to have this
water heater installed.
Schedule an appointment with
a qualied person to install your
water heater.
Call our Technical Assistance Ho-
tline which is listed on the water
heater’s warranty sheet.
Install a suitable drain pan
that is piped to an adequate
drain.
3
Set the water heater in place
taking care not to damage
the drain pan.
Most codes require seng
the water heater in a suitable drain
pan piped to an adequate drain. The
drain pan helps avoid property dam-
age which may occur from condensa-
on or leaks in the piping connecons
or tank. The drain pan must be at
least two inches wider than the diam-
eter of the water heater. Install the
drain pan so the water level is limited
to a maximum depth of 1-3/4”.
Verify that the water heater
is set in place properly. Check
that:
The T&P Relief Valve will not be in
contact with any electrical parts.
There is adequate space to install
the T&P Relief Valve discharge pipe
and that it can be piped to a sepa-
rate drain (and not into the drain
pan).
There is adequate access and space
around the water heater for future
maintenance.
7
Draining the old water heater.
Removing the T&P Relief Valve discharge pipe.

INSTALLATION