The story is all in the details. Every water heater that carries the A. O. Smith name has a reputation to live up to, one that we’ve earned through 140 years of innovation. As an industry leader, we constantly look for new materials and develop new technologies that can improve energy efficiency. So, when you choose an A. O.
TABLE OF CONTENTS RESIDENTIAL GAS Vertex™ High Efficiency Power Vent................................................1-2 Vertex™ High Efficiency Power Direct Vent......................................3-4 Polaris® High Efficiency...................................................................5-6 ProLine® XE Non-Condensing Power Vent.......................................7-8 ProLine® XE Non-Condensing Power Direct Vent..........................9-10 Effex® High Efficiency Atmospheric Vent....................
TABLE OF CONTENTS ProLine® XE Condensing High Efficiency.....................................65-66 ProLine® XE Non-Condensing Concentric Vent............................67-68 ProLine® XE Non-Condensing.....................................................69-70 ProLine® XE Non-Condensing Ultra-Low NOx.............................71-72 Non-Condensing Heavy-Duty......................................................73-74 Rack System................................................................................
COMMERCIAL TABLE OF CONTENTS CIRCULATING WATER HEATERS XP High Efficiency Water Heater............................................141-144 XP PLUS High Efficiency Water Heater.......................................145-148 Burkay® Genesis® Domestic Water Heater..............................149-150 Variable Fire™ High Efficiency Water Heater...........................151-152 HOT WATER SUPPLY BOILERS Burkay® Energy Saver Copper Heat Exchanger......................
Introducing the ProLine Family of Commercial-Grade Residential Water Heaters ® ProLine® XE Vertex™ ProLine® ProLine® Master When it comes to building a tough commercialgrade are water heater, outstanding the keys components to and success superior manufacturing capabilities. We’ve combined these two important elements to create the ProLine® Family of commercial-grade residential water heaters. This wholesale-channel exclusive will give A. O. Smith’s contractors the ultimate advantage.
WHY PROFESSIONALS CHOOSE A. O. SMITH Contractor Locator Contractor Rewards Program Brand Support It’s free and easy to participate. Enroll online at contractorrewards.com. Eligible products will have a yellow reward code label worth valuable points. Two ways to enter the codes: Profitable Contractors Contractor Tools & Support EARN POINTS BY PURCHASING A. O. SMITH WATER HEATERS Breadth of Product Line Advertising Resources 1. Download the smartphone app and scan the code. 2.
A. O. SMITH WATER HEATERS PREMIUM FEATURES. COMMERCIALGRADE RESIDENTIAL WATER HEATERS.
RESIDENTIAL GAS VERTEX™ HIGH EFFICIENCY POWER VENT Power Vent Design for Installation Versatility • Helical internal heat exchanger achieves 90% thermal efficiency, which saves money on operating costs compared to a standard 80% efficient gas water heater. • Combined horizontal and vertical vent runs terminating through an outside wall, using Schedule 40 PVC pipe as follows: • 2” pipe allows vent runs up to 25 equivalent feet. • 3” pipe allows vent runs up to 65 equivalent feet.
SIDE OUTLET H ANODE HOT B K COLD J C TOP VIEW * INSTALL IN ACCORDANCE WITH LOCAL CODES D OUTLET INLET E SIDE OUTLET T & P VALVE AN A B G DIAMETER J C SIDE INLET THERMOSTAT * INSTALL DRAIN VALVE D F E FRONT VIEW Model Number GPHE-50 Recovery @ BTU First Hour Gallon 90°F Rise Gallon Input Delivery Capacity Per Hour Per Hour Gallons 50 92 76,000 Approx.
RESIDENTIAL GAS VERTEX™ HIGH EFFICIENCY POWER DIRECT VENT Condensing Design • Operates at 96% thermal efficiency, which saves money on operating costs compared to a standard 80% efficient gas water heater. • Equipped with condensate drain tee. Helical Internal Heat Exchanger • Spiral heat exchanger keeps hot combustion gases in the tank longer to lengthen the heat transfer cycle. Power Direct Vent Design • Combined vertical and horizontal runs terminating through an outside wall.
ROUGH IN DIMENSIONS: 50 GALLON UNIT T&P ANODE UPPER SIDE CONNECT OUTLET F A C DIAMETER INLET B TOP VIEW LOWER SIDE CONNECT E *INSTALL IN ACCORDANCE WITH LOCAL CODES.
RESIDENTIAL GAS POLARIS® HIGH EFFICIENCY Condensing Design • Operates at up to 96% thermal efficiency which saves money on operating costs compared to a standard 80% efficient gas water heater. • Helical internal heat exchanger keeps hot combustion gases in the tank longer to extract more heat into the water. • Modulating burner maintains high efficiency operation at lower input rates.
Air Inlet Additional Side Taps Model Number Gallon Capacity BTU/h Input Gallon Per Hour Thermal Efficiency Recovery @ 90˚ Rise Gallon Per Hour Approx.
RESIDENTIAL GAS PROLINE® XE NON-CONDENSING POWER VENT Versatile Power Vent Design • All models feature an exclusive 3-position rotatable blower outlet which adds flexibility. • Combined horizontal and vertical vent runs up to 180 equivalent feet with 4” diameter venting (ABS, PVC, CPVC and polypropylene). • All models are equipped with a protected sensor that detects the presence of flammable vapors and automatically disables the burner to prevent ignition.
ANODE D COLD HOT Ø Model Number GPVL-40 GPVT-40 GPVL-50 GPVT-50 GPVX-50L †GPVX-75L Model Number Series 200 200 200 200 200 210 40 40 50 50 50 75 0.70 0.70 0.70 0.70 0.70 N/A 45 56 45 56 69 80 40,000 50,000 40,000 50,000 62,000 76,000 72 93 93 96 108 N/A 174 176 198 192 212 277 Dimensions in Inches A 59 GPVT-40 68-1/2 GPVL-50 60-1/8 GPVT-50 68-1/8 GPVX-50L 61-1/8 †GPVX-75L 70-5/8 GPVL-40 Recovery @ BTU Approx.
RESIDENTIAL GAS PROLINE® XE NON-CONDENSING POWER DIRECT VENT Power Direct Vent Design • Combined horizontal and vertical vent runs up to 180 equivalent feet with 4” diameter venting (ABS, PVC, CPVC and polypropylene). • Two-pipe sealed combustion system uses outside air, eliminating problems caused by insufficient indoor ventilation. Green Choice® Gas Burner • Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with LowNOx emission requirements of less than 40 ng/J.
D C A B G F Model Number Series 200 200 GPDX 50L 200 † GPDX 75L 210 GPDL 40 GPDT 50 Model Number First Recovery @ Approx. Energy Hour 90°F Rise Shipping Factor Rating Gallon Per Weight Gallon Hour (lb) Gallon Capacity Input BTU/h 40 50 50 75 40,000 45,000 62,000** 76,000 0.71 0.70 0.71 N/A 71 93 115 N/A 45.2 50.3 72.6 82.
RESIDENTIAL GAS EFFEX® HIGH EFFICIENCY ATMOSPHERIC VENT Pressurized Combustion System Installation Friendly • Allows for easy replacement of standard atmospheric vent heaters. • Easily connects to existing B-vent. Fan-Assisted, Category 1 Appliance • Plugs into standard 110/120V outlet (10 foot power cord included). 24V Electronic Controls Electronic Ignition LCD User Interface • Easy-to-read, eye level display. • Simple temperature settings and adjustments. • Service diagnostics are in plain text.
ANODE ROD G F ALVE H WITCH HOT CONNECTION VALVE COLD CONNECTION E TOP VIEW 1/2” DRAFT HOOD T&P VALVE C A F B GAS VALVE H ON/OFF SWITCH DRAIN VALVE CON D FRONT VIEW Model Number Gallon Capacity First Hour Rating Gallons Energy Factor (EF) BTU Input Gallon Per Hour GAHH-40 40 50 70 81 0.70 0.70 40,000 40,000 GAHH-50 Model Number GAHH-40 GAHH-50 Recovery Approx.
RESIDENTIAL GAS PROLINE® XE HIGH EFFICIENCY NON-CONDENSING FLUE DAMPER Automatic Flue Damper • Increases efficiency as it automatically opens and closes to reduce heat loss in the standby mode. Electronic Gas Control Diagnostics Electronic Ignition Dynaclean™ Diffuser Dip Tube Green Choice® Gas Burner • Patented eco-friendly burner design reduces NOx emissions by up to 33% and complies with LowNOx emission requirements of less than 40 ng/J.
ANODE ROD* HOT CONNECTION COLD CONNECTION E C T&P VALVE 1/2" GAS CONNECTION A B F D * Location for optional top-mounted T&P Valve if ordered from factory. Maximum Hydrostatic Working Pressure: 150 PSI. Model Number First Recovery @ Energy Gallon Hour 90°F Rise Factor Capacity Rating Gallon Per (EF) Gallons Hour BTU Input Gallon Per Hour Natural* Approx. Shipping Weight (lbs) Tall Models GCF-40 GCF-50 40 50 67 81 0.67 0.67 42 42 40,000 40,000 152 167 40 50 67 88 0.67 0.
RESIDENTIAL GAS PROLINE® XE HIGH EFFICIENCY NON-CONDENSING ULTRA-LOW NOx FLUE DAMPER ENERGY STAR® Efficiency • Eco-friendly non-CFC foam insulation and an automatic flue damper increase efficiency to provide maximum household annual operating cost savings. Green Choice® Gas Burner • Enhanced Ultra-Low NOx burner complies with SCAQMD Rule 1121 and other air quality management districts with similar requirements for NOx emissions of less than 10ng/J.
T&P VALVE (STANDARD LOCATION) HOT CONNECTION (ANODE OUTLET ON TOP T&P MODELS) COLD CONNECTION E C T&P VALVE (SHOWN AS OPTIONAL LOCATION) 1/2" GAS CONNECTION A B F D Maximum Hydrostatic Working Pressure: 150 PSI. Model Number Gallon Capacity First Hour Rating (Gallons) Energy Factor (EF) BTU Input Natural Gas Recovery @ 90F Rise (Gallon/ Hour) Approx. Shipping Weight GUF-40 40 50 74 90 0.67 0.
RESIDENTIAL GAS PROLINE® XE HIGH EFFICIENCY NON-CONDENSING ULTRA-LOW NOx POWER VENT Power Venting Made Simple • Thru-the-wall or thru-the-roof power venting using either 2” or 3” PVC. ABS or CPVC vent pipe. Intelli-Vent™ Gas Control • Advanced electronics for more precise control of water temperature and easy to understand system diagnostics.
40-GAL. = 25" 50-GAL. = 27" EXHAUST OUTLET BLOWER E Model Number Gallon Capacity First Hour Rating Gallon Per Hour GPNH-40 40 50 69 81 GPNH-50 Model Number GPNH-40 GPNH-50 Recovery BTU Approx. @ 90°F Energy Input Shipping Rise Factor Gallon Weight Gallon Per Per Hour (lbs) Hour 0.68 0.68 42.6 42.6 42,000 42,000 Dimensions in Inches 170 207 A B C D E Draft Hood 20 22 66-7/8 66-5/8 58-5/8 57-7/16 51-1/2 51 12-1/4 12-1/4 2 or 3 2 or 3 No option available for top T&P valve.
RESIDENTIAL GAS PROLINE® MASTER ATMOSPHERIC VENT Intelligent Control Logic* • The internal microprocessor provides enhanced operating parameters and tighter differentials for precise sensing and faster heating response to optimize performance. • Uses a thermopile to generate the power needed to operate the electronic gas control without requiring an external power source. • The electronic gas control incorporates an LED status indicator that monitors system operation and service diagnostics.
Model Number Gallon Capacity First Hour Rating Gallon Energy Factor BTU Input Natural Gas BTU Recovery Input 90°F Rise Propane Gallon Per Gas Hour 40 50 50 50 55 70 88 88 92 106 0.62 0.60 0.62 0.60 0.59 40,000 40,000 40,000 50,000 60,000 36,000 37,000 37,000 45,000 54,000 42 41 43 54 65 40 50 68 93 0.62 0.60 40,000 40,000 36,000 40,000 41 43 Tall Models HWR 40 HWG 50 HWR 50 HWRT 50* HWRX 55* Short Models HWRL 40 HWRL 50 Water connection is ¾” on all models.
RESIDENTIAL GAS PROLINE® MASTER ATMOSPHERIC VENT (CONTINUED) ANODE ROD (OPTIONAL T&P ANODE ROD LOCATION) (OPTIONAL T&P LOCATION) HOT CONNECTION HOT (ANODE OUTLET CONNECTION ON T&P MODELS) (ANODE OUTLET ON T&P MODELS) E C E C COLD CONNECTION COLD CONNECTION T&P VALVE T&P VALVE 1/2" GAS CONNECTION 1/2" GAS CONNECTION F F H H B B A A D G D G Maximum Hydrostatic Working Pressure: 150 PSI Maximum Hydrostatic Working Pressure: 150 PSI 21
Model Number Dimensions in Inches A B C D E 61-3/4 60-3/4 60-3/4 60-3/4 59-3/4 58-1/4 57-1/4 57-1/4 57-1/4 55-1/4 20 21 22 22 24 12-1/4 12-1/4 12-1/4 12-1/4 13-1/2 8 8 8 8 8 51-1/2 53-1/4 48 49-3/4 22 24 12 12 8 8 Tall Models HWR 40 HWG 50 HWR 50 HWRT 50* HWRX 55* Short Models HWRL 40 HWRL 50 Model Number Dimensions in Inches *G *H Draft Hood Approx.
RESIDENTIAL GAS PROLINE® MASTER ULTRA-LOW NOx The Electronic Gas Control Incorporates an LED Status Indicator that Monitors System Operation and Service Diagnostics High Energy Factors • Eco-Friendly non-CFC foam insulation, external heat traps and specially designed combustion chamber combine to produce a high Energy Factor for maximum savings on operating costs.
ANODE ROD (OPTIONAL T&P LOCATION) HOT CONNECTION (ANODE OUTLETON TOP T&P MODELS) COLD CONNECTION E T&P VALVE C F 1/2" GAS CONNECTION A B H G D Maximum Hydrostatic Working Pressure: 150 PSI Model Number Gallon Capacity First Hour Rating Gallon Energy Factor BTU Input Natural Gas 40 50 50 71 91 98 0.63 0.62 0.60 40,000 40,000 50,000 41 42 51 125 148 177 40 69 0.62 40,000 41 138 Recovery @ Approx.
RESIDENTIAL GAS PROLINE® HIGH RECOVERY ATMOSPHERIC VENT 75 & 100 GALLON Highest Recoveries • Capacity/input combinations up to 98 gallons/75,100 BTU’s to produce recoveries up to 81 gallons per hour. The Electronic Gas Control Incorporates an LED Status Indicator that Monitors System Operation and Service Diagnostics Green Choice® Gas Burner • Patented eco-friendly burner design reduces NOx emissions up to 33% and complies with LowNOx emission requirements of 40 ng/J.
TOP VIEW E TEMPERATURE AND PRESSURE RELIEF VALVE COLD HOT B H HOT WATER INLET COLD WATER INLET DRAIN VALVE GAS INLET T&P DRAIN VALVE C F B H A D G FRONT VIEW Model Number FCG-75 FCG-100 Model Number FCG-75 FCG-100 Model Number FCG-75 FCG-100 Gallon Capacity BTU Input Natural Gas Recovery @ 90°F Rise Gallon Per Hour 74 98 75,100 75,100 81 81 Approx.
RESIDENTIAL GAS PROLINE® DIRECT VENT Direct Vent Design • One-pipe, dual-channel closed system draws all make-up air from outside the home, eliminating problems caused by insufficient indoor ventilation and is FVIR compliant. • Horizontal air intake and venting on all models up to 80 inches from outside wall with no electrical power needed.
MINIMUM VENT 17” MAXIMUM VENT 80” 21º 6” DIA. ON 40 & 50 GAL. MODELS 3/4” MALE NPT OUTLET & INLET EXTERIOR WALL SIDE TAP AND T&P A FRONT E Model Gallon Number Capacity GDV-40 GDV-50 GDVT-50 Model Number GDV-40 GDV-50 GDVT-50 First Hour Rating Gallon 40 50 50 Recovery Input Energy 9OºF Rise Vent BTU Per Factor Gallon Per Outlet Hour Hour 72 91 92 0.63 0.62 0.61 38,000 40,000 47,000 41 43 51 Co-Axial Co-Axial Co-Axial Approx.
RESIDENTIAL GAS PROLINE® ATMOSPHERIC VENT Intelligent Control Logic* • The internal microprocessor provides enhanced operating parameters and tighter differentials for precise sensing and faster heating response to optimize performance. • Uses a thermopile to generate the power needed to operate the electronic gas control without requiring an external power source. • The electronic gas control incorporates an LED status indicator that monitors system operation and service diagnostics.
Model Number Recovery BTU Input BTU Input 90°F Rise Natural Propane Gallon Per Gas Gas Hour Gallon Capacity First Hour Rating Gallon Energy Factor 30 30 40 40 40 50 50 50 50 55 64 67 67 70 70 88 88 92 98 106 0.63 0.63 0.62 0.62 0.62 0.60 0.62 0.60 0.60 0.59 35,500 35,500 35,500 40,000 40,000 40,000 40,000 50,000 60,000 60,000 32,000 32,000 N/A 36,000 36,000 37,000 37,000 45,000 54,000 54,000 37 37 38 42 42 41 43 54 65 65 30 30 40 40 50 56 62 67 68 93 0.63 0.63 0.62 0.62 0.
RESIDENTIAL GAS PROLINE® ATMOSPHERIC VENT (CONTINUED) ANODE ROD (OPTIONAL T&P ANODE ROD LOCATION) (OPTIONAL T&P LOCATION) HOT CONNECTION HOT (ANODE OUTLET CONNECTION ON T&P MODELS) (ANODE OUTLET ON T&P MODELS) E C E C COLD CONNECTION COLD CONNECTION T&P VALVE T&P VALVE 1/2" GAS CONNECTION 1/2" GAS CONNECTION F F H H B B A A D G D G Maximum Hydrostatic Working Pressure: 150 PSI Maximum Hydrostatic Working Pressure: 150 PSI 31
Model Number Dimensions in Inches A B C D E 61-1/2 61-1/2 61-3/4 61-3/4 61-3/4 60-3/4 60-3/4 60-3/4 65-1/2 59-3/4 58 58 58-1/4 58-1/4 58-1/4 57-1/4 57-1/4 57-1/4 61 55-1/4 16 18 20 18 20 21 22 22 22 24 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 13-1/2 13-1/2 8 8 8 8 8 8 8 8 8 8 50 50 51-1/2 51-1/2 53-1/4 46-1/2 46-1/2 48 48 49-3/4 18 20 20 22 24 12 12 12 12 12 8 8 8 8 8 Tall Models †GCB-30 GCR-30 ‡GCRH-40 †GCB-40 GCR-40* GCG-50* GCR-50* GCRT-50* †GCRX-50* GCRX-55* Short Models †
RESIDENTIAL GAS PROLINE® ENERGY SAVER ATMOSPHERIC VENT MOBILE HOME Complies with HUD Standards for Manufactured Housing Installation Gas Control Convertible for Natural and Propane Gas • For flexibility to meet the varying needs of manufactured housing installations. Side-Mounted 3/4” Cold Water Inlets • For flexibility to meet the varying needs of manufactured housing installations. • Top-mounted 3/4” hot water outlet.
ANODE ROD HOT WATER OUTLET CONNECTION 3/4˝ NIPPLE SUPPLIED T&P VALVE A B C F COLD WATER INLET CONNECTION, 3/4˝ NIPPLE SUPPLIED E D GAS CONNECTOR 1/2˝ FEMALE Model Number FMHR-30 FMHR-40 Recovery First BTU Input BTU Input Approx. @ 90°F Gallon Hour Energy Per Hour Per Hour Shipping Rise Capacity Rating Factor Natural Propane Weight Gallon Gallon Gas Gas (lbs) Per Hour 30 40 55 62 0.63 0.
RESIDENTIAL GAS PROLINE® ENERGY SAVER DIRECT VENT MOBILE HOME Complies With HUD Standards For Manufactured Housing Installation Gas Control Convertible for Natural and Propane Gas • For flexibility to meet the varying needs of manufactured housing installations. Direct Vent Models Package with Bottom Intake Air Vent • To draw all combustion make-up air from outside the structure. Optional Ducted Air Inlet Kit for Direct Vent Models • For use when water heater is installed over a basement.
ANODE ROD HOT WATER OUTLET CONNECTION 3/4˝ NIPPLE SUPPLIED T&P VALVE A B C F COLD WATER INLET CONNECTION, 3/4˝ NIPPLE SUPPLIED E D GAS CONNECTOR 1/2˝ FEMALE Btu Recovery First Btu Approx. Input @ 90°F Model Gallon Hour Energy Input Vent Shipping Per Hour Rise Number Capacity Rating Factor Per Hour Outlet Weight Natural Gallon Gallon Propane (lbs) Gas Per Hour FMDV-30 FMDV-40 FMDV-50 Model Number FMDV-30 FMDV-40 FMDV-50 30 40 50 49 61 74 0.63 30,000 29,000 0.62 32,000 29,000 0.
RESIDENTIAL GAS PROLINE® ULTRA-LOW NOx The Electronic Gas Control Incorporates an LED Status Indicator that Monitors System Operation and Service Diagnostics High Energy Factors • Eco-Friendly non-CFC foam insulation, external heat traps and specially designed combustion chamber combine to produce a high Energy Factor for maximum savings on operating costs.
ANODE ROD (OPTIONAL T&P LOCATION) HOT CONNECTION (ANODE OUTLETON TOP T&P MODELS) COLD CONNECTION E T&P VALVE C F H 1/2" GAS CONNECTION A B G D Maximum Hydrostatic Working Pressure: 150 PSI Model Gallon Number Capacity Recovery @ First Hour BTU Input Approx. Energy 90°F Rise Rating Natural Shipping Factor Gallon Per Gallon Gas Weight (lbs) Hour Tall Models GUC-30 GUC-40 GUR-40 GUC-50 GUR-50 GURT-50L* 30 40 40 50 50 50 55 71 71 91 91 98 0.63 0.62 0.63 0.60 0.62 0.
RESIDENTIAL GAS PROLINE® ULTRA-LOW NOx DIRECT VENT Flammable Vapor Resistant/Direct Vent Sealed Combustion System Durable, Ultra-Low NOx Burner Construction Non-CFC Foam Insulation • The tank is surrounded by a thick coat of non-CFC polyurethane foam to trap heat inside the tank, saving energy.
TOP VIEW 5˝ HOT OUTLET 17˝/22˝ MIN. 80˝ MAX. HORIZONTAL VENT E COLD INLET MAX. HEIGHT IS 68˝ ABOVE TOP OF HEATER THRU-THE-WALL INSTALLATION OUTLET C T&P VALVE T&P VALVE A B F H GAS VALVE D INLET G SIDE VIEW FRONT VIEW Gallon Model Number Capacity GDNL-40L-100 GDNT-50L-100 Recovery @ 90°F Energy Rise Factor Gallon Per Hour First Hour Rating Gallon 40 50 59 81 0.62 0.62 39 41 BTU Input Per Hour Approx.
RESIDENTIAL GAS PROLINE® ULTRA-LOW NOx HIGH RECOVERY Fully Automatic Controls with Safety Shutoff Heavy Gauge Steel Jacket Blue Diamond® Glass Coating Foam Insulation Ultra-Low NOx Emissions • Complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar requirements of 14 ng/J or 20 ppm. Easy-To-Install • Completely factory-assembled. Only gas, water and vent connections need to be made.
TOP VIEW TER T H TEMPERATURE AND PRESSURE RELIEF VALVE C COLD HOT G B DRAIN VALVE K HOT WATER OUTLET L GAS INLET K COLD WATER INLET F J DRAIN VALVE D B A E M Model Number Gallon Recovery @ 90°F Capacity Rise Gallon Per Hour BTU Input Per Hour Approx.
RESIDENTIAL ELECTRIC VOLTEX® HYBRID ELECTRIC HEAT PUMP Increased Energy Efficiency • Reduce water heating costs up to 71% compared to a standard electric water heater. • Up to a 3.24 Energy Factor (EF) Rating conserves energy and meets ENERGY STAR® qualifications. Dual Voltage Capable • 208/240 VAC 60Hz capable for use in almost any residential installation.
A B C E D Model Number Gallon Capacity HPTU-50N 50 66 80 HPTU-66N HPTU-80N Model Number HPTU-50N HPTU-66N HPTU-80N 1st Hour Rating (Gal) By Mode Energy Factor by Mode Efficiency Hybrid Electric Efficiency Hybrid Electric 3.61 3.44 3.27 3.24 3.17 3.06 0.93 0.92 0.92 44.4 62.5 76.3 70 80 95 Dimensions in Inches 57.3 78.6 90.1 A B C D E Approx. Shipping Weight (lbs) 63 61 69 22 27 27 40-5/8 38 46 3-3/4 4 4 40-1/2 38 46 196 289 307 Requires 30 amp breaker.
RESIDENTIAL ELECTRIC VOLTEX® HYBRID ELECTRIC HEAT PUMP Increased Energy Efficiency • Reduce water heating costs up to 71% compared to a standard electric water heater. • Up to a 3.24 Energy Factor (EF) Rating conserves energy and meets ENERGY STAR® qualifications. Dual Voltage Capable • 208/240 VAC 60Hz capable for use in almost any residential installation.
A B C E D Model Gallon Number Capacity 1st Hour Rating (Gal) by Mode Energy Factor by Mode Efficiency Hybrid FPTU-80 3.61 3.44 3.27 Model Number A B C D E Approx. Shipping Weight (lbs.) 63 61 69 22 27 27 40-5/8 38 46 3-3/4 4 4 40-1/2 38 46 196 289 307 FPTU-66 FPTU-50 FPTU-66 FPTU-80 3.24 3.17 3.06 Electric Efficiency Hybrid Electric 50 66 80 FPTU-50 0.93 0.92 0.92 44.4 62.5 76.3 70 80 95 Dimensions in Inches 57.3 78.6 90.1 Requires 30 amp breaker.
RESIDENTIAL ELECTRIC PROLINE® XE ELECTRONIC DISPLAY Electronic User Interface • Touchscreen display. • Multiple operating modes help save money. • Energy Saver and vacation modes available. • Diagnostic feedback. • Dry fire protection. • Grid management ready. • CEA-2045 Bridge module compatible. Enhanced Heating Elements • Dual 5500 watt elements for the fastest recovery and reliable operation. • Incoloy stainless steel elements last longer than standard copper elements.
ANODE SMART PORT MODULE CONNECTION T&P VALVE JUNCTION BOX T&P VALVE ACCESS PANEL & USER INTERFACE ENERGY SMART S TANDARD VAC ATION GRID ENABLED F °F/°C ACCESS PANEL DRAIN VALVE Model Number Gallon Capacity First Hour Rating Gallon Energy Factor Recovery @ 90˚F Rise Gallon Per Hour Approx. Shipping Weight (lbs) 40 50 55 54 67 79 0.95 0.95 0.94 25 25 25 118 134 145 40 50 56 67 0.95 0.
RESIDENTIAL ELECTRIC PROLINE® MASTER STANDARD Commercial-Grade Heating Elements • Dual 4500 watt elements for the fastest recovery and reliable operation. • Long-lasting dual stainless steel elements last longer than standard copper elements. High Energy Factors DynaClean™ Diffuser Dip Tube CoreGard™ Anode Rod • ProLine® Master products have increased anode protection with either longer or multiple anodes, depending on model. Code Compliance • Meets UBC, CEC and HUD National Codes.
ANODE JUNCTION BOX T&P VALVE T&P VALVE ACCESS PANEL ACCESS PANEL DRAIN VALVE Model Number Gallon Capacity First Hour Rating Gallon Energy Factor Recovery @ 90°F Rise Gallon Per Hour 40 50 55 50 73 76 0.95 0.95 0.94 21 21 21 40 50 55 62 0.95 0.
RESIDENTIAL ELECTRIC PROLINE® STANDARD Enhanced Heating Elements • Dual 4500 watt elements for the fastest recovery and reliable operation. • Incoloy stainless steel lower element lasts longer than standard copper elements. High Energy Factors DynaClean™ Diffuser Dip Tube CoreGard™ Anode Rod Code Compliance • Meets UBC, CEC and HUD National Codes. • Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IES 90.1.
Model Number Gallon Capacity First Hour Rating Gallon Energy Factor 30 40 50 55 47 50 73 76 0.95 0.95 0.95 0.94 21 21 21 21 4500 4500 4500 4500 6000 6000 6000 6000 30 30 40 50 48 49 55 62 0.95 0.95 0.95 0.95 21 21 21 21 4500 4500 4500 4500 6000 6000 6000 6000 0.95 0.95 0.95 0.95 0.
RESIDENTIAL ELECTRIC MOBILE HOME Approved for Manufactured Housing • All residential electric water heaters are compliant with HUD standards for mobile homes/ manufactured housing. Side Water Connections • For ease of installation in mobile home applications. CoreGard™ Anode Rod • Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods.
ANODE C JUNCTION BOX T&P VALVE WATER CONNECTIONS T&P VALVE OUTLET C E INLET MHE6-30H-030D MHE6-30H-035D MHE6-40R-030D MHE6-40R-035D MHE6-30L-030D* MHE6-30L-035D* First Gallon Hour Capacity Rating Gallon 30 30 40 40 28 28 42 42 51 51 40 40 Recovery Approx. Energy @ 90˚F Rise Shipping Voltage Factor Gallon Per Weight Hour (lbs) 0.95 0.95 0.95 0.95 0.95 0.
RESIDENTIAL ELECTRIC PROLINE® SPECIALTY ELECTRIC Approved For Manufactured Housing • All residential electric water heaters are compliant with HUD standards for mobile homes/manufactured housing. Table-Top • Features a convenient flat porcelain surface at 36" height, providing extra "counter space" wherever installed. All plumbing and electrical connections are made through the back of the water heater. This heater is equipped with a PEX cross-linked polymer dip tube.
Model Number Gallon Capacity First Hour Rating Gallon Energy Factor Compact Models 6 10 19 19.9 EJC-6 EJC-10 EJCS-20 EJCT-20 Element Wattage Standard 240V 3000 6000 6000 6000 N/A N/A N/A N/A N/A N/A N/A N/A 1650 1650 2500 2500 28 28 38 38 39 39 47 44 0.95 0.95 0.95 0.95 4500 4500 4500 4500 38 45 0.88 4500 Lowboy Side-Connect Model ENJB-30* ENJ-30 ENJB-40* ENJ-40 240V Table Top Model ESTT-40 Model Number 6000 6000 6000 6000 240V Point-Of-Use-Models 5500 120V 2.
RESIDENTIAL PUMP TANKS Certified to NSF/ANSI 61-G and 372 ultiple Head Construction Adds Structural Strength and More M Capacity within the Same Diameters • Interior powder coating is permanently bonded to the tank shell for ultimate protection on the water side of the tank. • Butyl rubber parabolic diaphragm. • Positive lock retention system controls compression in the diaphragm connection, eliminating air loss or water leaks in tank.
Dimensions in Inches Model Number Volume Connecting (Gallons) NPT Size Overall Height -A Weight To Center of Water Diameter-B (lbs.) Inlet PMI (Inline) and PM (Free-Standing) Series PMI-2 PMI-5 PMI-7 PMI-14 PM-14 PM-20 PM-26 PM-32 PM-45 PM-65 PM-85 PM-86 PM-119 2.0 4.6 7.3 13.9 13.9 19.9 25.9 31.8 45.2 65.1 84.9 83.5 115.9 3/4 (M) 3/4 (M) 3/4 (M) 1 (M) 1 (F) 1 (F) 1 (F) 1 (F) 1-1/4 (F) 1-1/4 (F) 1-1/4 (F) 1-1/4 (F) 1-1/4 (F) Horizontal Series PMH-7 PMH-14 PMH-20 7.3 13.9 19.
RESIDENTIAL EXPANSION TANKS Interior Powder Coating is Permanently Bonded to the Tank Shell for Ultimate Protection on the Inside of the Tank Butyl Rubber Parabolic Diaphragm Positive Lock Retention System Controls Compression in the Diaphragm Connection, Eliminating Air Loss or Water Leaks in Tank Projection Welded Air Valve 5-Year Limited Warranty on PMC Expansion Tanks Certified to NSF/ANSI 61-G and 372 When used in potable applications 59 1-Year Limited Warranty on Hydronic Expansion Tanks
Model Number Maximum (psig) Working Pressure Tank Volume (Gallons) Maximum Accepted Volume (Gallons) 20 psi 40 psi 60 psi PMC-Series (Potable Expansion Tanks - 5-Year Limited Warranty) PMC-10 150 9.25 7.80 6.55 5.25 PMET-Series (Hydronic Expansion Tanks - 1-Year Limited Warranty) PMET-2 PMET-5 PMET-7 PMET-14 Model Number 100 100 100 100 Connection NPT Size 1.96 4.55 7.30 14.6 1.53 3.75 4.60 10.
TANKLESS RESIDENTIAL PROLINE® XE CONDENSING WITH RECIRCULATION PUMP Integrated Recirculation Pump • 1/2" pipe - 100' • 3/4" pipe - 500' Pump Controls • Included with heater • Two timer settings • Adjustable differential settings ENERGY STAR® Qualified Ultra-Low NOx Emissions • Complies with SCAQMD 1146.
17-3/4" (450 mm) 15" (381 mm) 7" (180 mm) INDOOR MODEL 11-1/4" (285 mm) 5-3/4" (147 mm) Φ 4" (102 mm) Female Exhaust 2-5/8" (65 mm) Intake 2-5/8" (68 mm) Φ 4" (102 mm) Female 24-7/8" (631 mm) 23-5/8" (600 mm) 6-1/4" (159 mm) 1/2 (13 mm) RETURN 4-5/8" (117 mm) GAS 5-1/8" (131 mm) Drain port 6-1/4" (159 mm) HOT 6-1/2" (164 mm) COLD 6-3/4" (172 mm) 120 VAC 3-7/8" (174 mm) Condensate drain port 7-7/8" (199 mm) 540P Outdoor (AT-H3P-OS) COLD 5/8" (17 mm) GAS 5-3/4" (147 mm) Condensate drain port 7-1/2" (
TANKLESS RESIDENTIAL PROLINE® XE CONDENSING HIGH EFFICIENCY ENERGY STAR® Qualified Condensing Technology Provides 0.93 Energy Factor (EF) Ultra-Low NOx Emissions • Complies with SCAQMD 1146.2 NOx emission requirements of 14 ng/J or 20 PPM. Copper Primary Heat Exchanger • 25x better heat transfer than stainless steel thus stabilizing outgoing water temperature quicker and reducing pressure drop across the heat exchanger.
INDOOR MODEL INDOOR MODEL Front view Side view 13-7/8" (352mm) 10" (254mm) 6-1/4" (158.5mm) 4" (102mm) 4" (102mm) 2-9/16" (64.8mm) 2-3/4" (70.2mm) 10-13/16" (274.6mm) 10-5/16" (262.2mm) 6" (152.1mm) 24" (609.4mm) 22-7/8 (580mm) 58.4 Hot 4-3/4" (121.1mm) Condensate drain port 5-1/16" (129.1mm) 1" (25.5mm) Condensate drain port 3-1/4" (82.1mm) Gas 4-1/8" (105.4mm) Hot 6-1/2" (164.6mm) Cold 7" (178.5mm) 120VAC 7-3/4" (196.5mm) Cold 1/2" (13.
TANKLESS RESIDENTIAL & COMMERCIAL PROLINE® XE CONDENSING HIGH EFFICIENCY ENERGY STAR® Qualified Condensing Technology Provides 0.95 Energy Factor Ultra-Low NOx Emissions • Complies with SCAQMD 1146.2 NOx emission requirements of 14 ng/J or 20 PPM. Maximum Flow Rates up to 10.0 GPM Heat Exchanger • Primary heat exchanger of the ATI/ATO-540 is constructed of a commercial-grade copper that is more resilient to erosion.
INDOOR MODEL INDOOR MODEL 11-1/4" (285 mm) 4" (101 mm) 4" (102 mm) Female Exhaust 2-5/8" (65 mm) 5-3/4" (147 mm) 22-1/2" (570 mm) 24-7/8" (631 mm) 23-5/8" (600 mm) 6-1/4" (159mm) Intake 2-5/8" (68 mm) 17-3/4" (450 mm) 7" (180 mm) 4" (102 mm) Female 10-3/4" (272mm) HOT 4-3/4" (120 mm) Drain port 6-3/4" (170 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (140 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 120 VAC 6-7/8" (174 mm) Condens ate drain port 7-7/8" (199 mm) COLD 5/8" (17 mm) 120 VAC 3
TANKLESS RESIDENTIAL PROLINE® XE NON-CONDENSING CONCENTRIC VENT Concentric Vent Design • Power direct vent • Vertical or horizontal venting up to 43’ Field Convertible from Natural Gas to Propane Ultra-Low NOx Emissions • Complies with SCAQMD Rule 1146.2 NOx emission requirements of 14 ng/J or 20 PPM. Maximum Flow Rates up to 10.0 GPM Primary Heat Exchanger • Primary heat exchanger of the ATI-510C is constructed of a commercial-grade copper that is more resilient to erosion.
5-7/16” (137.7 mm) Top view 13-3/4” (350 mm) 10-1/2” (266.5 mm) 5-7/16” (137.7 mm) 20-1/2” (520 mm) 19-1/2” (495.7 mm) 1.0” (25.5 mm) Side view 7-9/16” (192.3 mm) 6-3/8” (162.3 mm) 4-1/4” (107.8mm) 5-11/16” (145mm) Front view Cold 1-5/8” (42.0 mm) 120 VAC 2-1/4” (57 mm) Hot 4-1/8” (105.4 mm) Gas 4-13/16” (122.1) Bottom view Model Number* ATI-110C-N ATI-310C-N ATI-510C-N Gas Consumption Input Inlet Gas Pressure** Minimum (BTU/H) Maximum (BTU/H) Minimum (in. W.C.) Maximum (in. W.C.
TANKLESS RESIDENTIAL & COMMERCIAL PROLINE® XE NON-CONDENSING Maximum Flow Rates up to 10.0 GPM Copper Primary Heat Exchanger • Primary heat exchanger of the ATI/ATO-510 is constructed of a commercial-grade copper that is more resilient to erosion.
INDOOR MODEL (DIMENSIONS FOR 310/510 MODELS) ∅4 (101 mm) 4-3/8" (113 mm) 20-1/4" (520mm) 1-3/8" (36 mm) 1-7/8" (47 mm) HOT 4-5/8" (116 mm) 1-3/4" (45mm) 4-3/8" (113mm) 7-7/8" (203mm) 1-3/4" (45mm) 5" (128mm) 13-1/8" (334 mm) 5-1/8" (130 mm) 1-7/8" (47mm) COLD 3-1/4" (84mm) 120V 1-3/8" (36mm) HOT 5-1/4" (133mm) GAS 4-7/8" (124mm) ATI-110-N ATI-510-N 19-3/8" (493mm) 120 VAC 1-7/8" (49 mm) GAS 4-1/4" (109 mm) COLD 5" (127 mm) 120 VAC 1-1/2" (37 mm) 4-3/8" (113 mm) 1-5/8" (43mm) HOT 5" (127 m
TANKLESS RESIDENTIAL & COMMERCIAL PROLINE® XE NON-CONDENSING ULTRA-LOW NOx Ultra-Low NOx Emissions • Complies with SCAQMD 1146.2 NOx emission requirements of 14 ng/J or 20 PPM. Field Convertible from Natural Gas to Propane Maximum Flow Rates Up To 10.0 GPM Copper Primary Heat Exchanger • Primary heat exchange of the ATI/ATO-510U is constructed of a commercial-grade copper that is more resilient to erosion.
INDOOR MODEL 13-3/4" (350 mm) 10" (254 mm) 4-3/8" (113mm) 1-3/4" (45 mm) 20-1/2" (520 mm) HOT 4-5/8" (116 mm) 13-1/8" (334 mm) 5-1/8" (130 mm) 4-3/8" (113 mm) OUTDOOR MODEL 13-3/4" (350 mm) 10" (254 mm) 8" (203 mm) 1-3/4" (45 mm) 19-3/8" (493 mm) 21-1/2" (545 mm) 1-3/4" (45 mm) 1" (26 mm) 120 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 10" (256 mm) 120 VAC 1-5/8" (40 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm) 1-5/8" (43 mm) 120VAC 1-7/8" (49 mm) GAS 4-1/4" (109 mm) COLD 5"
COMMERCIAL TANKLESS NON-CONDENSING HEAVY-DUTY Commercial-Grade Copper Heat Exchanger (Non-ASME Models) ASME Models Available 5” Category III Stainless Steel Venting Vertical or Horizontal Venting Installation Power Vent or Convertible to Power Direct Vent Electronic Ignition Low NOx Emissions Combined Indoor/Outdoor Models Easy-Link up to 4 Units Multi-Link up to 10 Units Warranty • 6-year limited warranty on heat exchanger • 5-year limited warranty on all parts 73
24-7/8" (632.9mm) 12-1/4" (311.5mm) 15" (381mm) 4-7/8" (122.9mm) 8" (203mm) 1/2" (11.9mm) 28-7/8" (734mm) 25-1/4" (642mm) 2-1/2" (62.1mm) 5" (127mm) 1/2" (12.5mm) 4-3/8" (110.8mm) GAS -3/8" (137.3mm) HOT 7-3/8" (186mm)GAS 5-7/8" (150mm) HOT 7-5/8" (194.3mm) COLD Model Number* 4" (100mm) 120V 1-5/8" (40mm) COLD 6-3/4" (171.3mm) 120V Gas Consumption Input Inlet Gas Pressure** Type Minimum (BTU/H) Maximum (BTU/H) Minimum (in. W.C.) Maximum (in. W.C.
COMMERCIAL TANKLESS RACK SYSTEM Multiple Design and Installation Configurations • Wall mount, freestanding in-line, and freestanding back-to-back designs • Indoor and outdoor rack designs • Uses the 540H high efficiency condensing tankless heaters.
Model Number Number of Heaters Btuh Input Min Max Max Flow (GPM) @ 40˚F @ 100˚F @ 140˚F Rise Rise Rise Freestanding ATI-CRS-2IL-N 2 15,000 398,000 18.8 7.6 5.4 ATI-CRS-3IL-N 3 15,000 597,000 28.2 11.4 8.1 ATI-CRS-4IL-N Wall Mount ATI-CRS-2WM-N 4 15,000 796,000 37.6 15.2 10.8 2 15,000 398,000 18.8 7.6 5.4 ATI-CRS-3WM-N 3 15,000 597,000 28.2 11.4 8.
COMMERCIAL TANKLESS RACK SYSTEM (CONTINUED) Freestanding C Pipe Lengths: 46 in. plus fittings 42.00 in. SEE NOTE 1 20 in. (INLETS) 20 in. (EXHAUSTS) SEE NOTE 2 A 58-3/4 in. SEE NOTE 2 4.33 in. (GAS) 13.28 in. (HOT) Front 17.40 in. (COLD) B 13 in. Bottom Back NOTES: 1. TOP-MOUNTED AIR SUPPLY INLET/EXHAUST VENTS ARE USED WITH INDOOR MODELS ONLY. 2. MOUNTING BRACKETS ADJUST HORIZONTALLY ALONG CHANNEL SLOTS. 3. INDOOR AND OUTDOOR RACK SYSTEMS HAVE IDENTICAL DIMENSIONS.
Back-to-Back C Pipe Lengths: 46 in. plus fittings SEE NOTE 1 20 in. (INLETS) 22.00 in. 20 in. (EXHAUSTS) A 60-1/2 in. 43-1/8 in. Front Right MOUNTING BRACKETS (x4) SEE NOTE 2 B 34-1/2 in. NOTES: 1. TOP-MOUNTED AIR SUPPLY INLET/EXHAUST VENT ARE USED WITH INDOOR MODELS ONLY. 2. MOUNTING BRACKETS ADJUST HORIZONTALLY ALONG CHANNEL SLOTS. 3. INDOOR AND OUTDOOR RACK SYSTEMS HAVE IDENTICAL DIMENSIONS. EXCEPTION: INDOOR MODELS HAVE TOP-MOUNTED INTAKES AND EXHAUSTS. OUTDOOR MODELS DO NOT. 37-3/4 in.
COMMERCIAL WATER SYSTEMS BUILDING MANAGEMENT SYSTEM BACnet & MODBUS INTERFACE Connect Your A. O. Smith Water Heater to your Building Management System Using the New Millennium Control from ICC (Industrial Control Communications, Inc.
INTRODUCING THE BMS GATEWAY FOR CONTROL OF A. O.
COMMERCIAL GAS CYCLONE® HE Power Vent Design for Installation Versatility • Helical internal heat exchanger achieves 90% thermal efficiency, which saves money on operating costs compared to a standard 80% efficient gas water heater.
SIDE OUTLET H ANODE HOT B K COLD J C TOP VIEW * INSTALL IN ACCORDANCE WITH LOCAL CODES D OUTLET INLET E SIDE OUTLET T & P VALVE ANOD A B G DIAMETER J C SIDE INLET THERMOSTAT * INSTALL IN DRAIN VALVE F D E FRONT VIEW Model Number BTX-80 Gallon Capacity Recovery Capacity GPH @ 100°F Rise BTU Input Per Hour Approx.
COMMERCIAL GAS CYCLONE® Xi Condensing Design • Operates at 96% thermal efficiency, which saves money on operating costs compared to a standard 80% efficient gas water heater.
ANODE F BTX-100 AN OUTLET INLET TOP VIEW INSTALL IN ACCORDANCE WITH LOCAL CODES. 3” DIAMETER VENT/EXHAUST OUTLET 1 3/ 16 ” 4 1/2” DI AMET ER INSTALL IN ACC 1 1/2” 21 1/8” 3” DIAMETER VENT/EXHAUST N AI R 39” 3” DIAMETER PVC INTAKE/COMBUSTIO OPTIONAL CONCENTRIC VENT KI T 1 3/ 1 1/2” 3” DIA INTAK FRONT VIEW Model Number BTX-100 Model Number BTX-100 OPTION Capacity Gallons Recovery Capacity GPH @ 100°F Rise BTU Input Per Hour Approx.
COMMERCIAL GAS CYCLONE® Xi Condensing Design • Operates at 96% thermal efficiency, which saves money on operating costs compared to a standard 80% efficient gas water heater.
BTXL-100 ANODE INLET F TOP VIEW DES. OUTLET INLET TOP VIEW R INSTALL IN ACCORDANCE WITH LOCAL CODES. T T 4 1/2” DI AMET ER 1 3/ 16 ” 21 1/8” 3” DIAMETER PVC INTAKE/COMBUSTIO N AI R 39” OPTIONAL CONCENTRIC VENT KIFRONT T Model Number BTXL-100 Model Number BTXL-100 VIEW Capacity Gallons Recovery Capacity GPH @ 100°F Rise BTU Input Per Hour Approx.
COMMERCIAL GAS CYCLONE® MXi—MODULATING High Efficiency Modulating Pre-Mix Powered Burner • Down-fired pre-mix burner provides optimum efficiency and quiet operation • Top-mounted burner position prevents condensation from affecting burner operation Up to 98% Efficient Intelligent Control System with Touch Screen Display • Exclusive A. O.
Model Number Gallon Capacity Input BTU/HR BTH-120(A) 60 100 100 100 119 119 119 120,000 150,000 199,900 250,000 300,000 399,000 499,000 BTH-150(A) BTH-199(A) BTH-250(A) BTH-300(A) BTH-400(A) BTH-500(A) Approx. Approx. Shipping Weight Shipping Weight (lbs) Std (lbs) ASME 460 523 523 523 855 855 855 490 553 553 553 855 855 855 Optional Concentric Vent Kits 100111100 (BTH-120 through BTH-250 models). 100113124 (BTH-300 through BTH-500 models). Electrical characteristics- 120V-60 Hz A.C., 5.0A.
OUTLET COMMERCIAL GAS T T& PV AL VE C LE AN US HA EX IN DRA E VALV O U T FRONT CYCLONE® MXi—MODULATING 18° 42° 30° 45° (CONTINUED) * Center line of water outlet on top of the water heaters is approximately 7 inches from the front edge of the water heater.
T&P FRONT E CLEANOUT D 3/4" NPT RECIRC RETURN 20° J INT AKE G C 1 1/2" NPT WATER OUTLET 1 1/2" SUPPLY GAS CONNECTION 4" PVC AIR INTAKE GAS CONNECTION TOP T& P 45° 18° 30° 42° T US HA EX WATER OUTLET HEIGHT DRA IN 1 1/2" NPT WATER INLET CL EA NO UT A 4" EXHAUST VENT CONNECTION GAS 70° 3/4" NPT DRAIN FRONT BACK F H B Model Number BTH-300(A) BTH-400(A) BTH-500(A) Model Number BTH-300(A) BTH-400(A) BTH-500(A) I Dimensions in Inches A B C D E 4.75 4.75 4.75 33.12 33.12 33.
COMMERCIAL GAS POLARIS® HIGH EFFICIENCY Condensing Design • Operates at up to 96% thermal efficiency which saves money on operating costs compared to a standard 80% efficient gas water heater. • Helical internal heat exchanger keeps hot combustion gases in the tank longer to extract more heat into the water. • Modulating burner maintains high efficiency operation at lower input rates.
Air Inlet Additional Side Taps Model Number Gallon Capacity BTU/h Input Gallon Per Hour Thermal Efficiency Recovery @ 90˚ Rise Gallon Per Hour BSS 130 34 34 50 50 50 50 130,000 150,000 130,000 150,000 175,000 199,000 96% 94% 95% 95% 96% 96% BSS 150 BTS 130 BTS 150 BTS 175 BTS 199 Model Number Vent Connection BSS 130 2 or 3 2 or 3 2 or 3 2 or 3 3 3 BSS 150 BTS 130 BTS 150 BTS 175 BTS 199 1" Water Connections C 15-3/4 15-3/4 15-3/4 15-3/4 15-3/4 15-3/4 D T&P E 40-1/2 41 40-1/2 41 54-1/2 5
COMMERCIAL GAS MASTER-FIT® BTR The Eliminator™ Self-Cleaning System • Designed to significantly reduce or eliminate sediment build-up inside the tank • Reduced sediment build-up maintains rated thermal efficiency and reduces water heating costs • Self-cleaning system maximizes tank life Factory-Installed Draft Diverter and Automatic Flue Damper (BTR-120-400 Models) • BTR-500 Model features induced draft design and no damper • Low-profile draft diverter helps for installation in tight spaces • Automatic mo
Model Number BTR-120* BTR-154 BTR-180 BTR-197 BTR-198 BTR-199 BTR-200 (A) BTR-250* (A) BTR-251* (A) BTR-275* (A) BTR-305 (A) BTR-365 (A) BTR-400 (A) BTR-500 (A) Gallon Capacity Input BTU/HR Natural Gas Recovery Capacity GPH @ 100°F Rise 71 81 81 100 100 81 100 100 65 100 65 85 100 85 120,000 154,000 180,000 199,000 199,000 199,000 199,000 250,000 251,000 275,000 305,000 365,000 390,000 500,000 116 149 175 193 193 193 193 242 243 267 296 354 378 485 Specify when ordering propane (LP) gas.
COMMERCIAL GAS MASTER-FIT® BTR (CONTINUED) Master-Fit BTR 120-400 INDU I 1˝ NPT RELIEF VALVE OPENING OUTLET C H D INLET A J E B G 1˝ CLEARANCE GAS CONNECTION MODEL BTR-120-400 TOP INLET TOP OUTLET F Master-Fit BTR 500 INDUCED DRAFT MOTOR I A MODEL R-120-400 95 MODEL BTR-500
Model Number Dimensions in Inches A B C D E F BTR-120* 69-3/4 4-1/4 59-1/2 50-7/8 19-11/16 19 BTR-154 73 67-1/2 75 75 67-1/2 72 72 75 72 75 79-1/2 75-1/2 81-1/2 4-1/4 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 4-1/2 17-1/2 66-1/2 62 70 70 62 65-1/8 65-1/8 65-3/4 65-1/8 65-3/4 70-1/4 67-1/2 77-1/4 57-7/8 53-5/8 61-5/8 61-5/8 53-5/8 55-7/8 55-7/8 57-1/4 55-7/8 57-1/4 62-1/2 58-1/4 67-1/2 19-11/16 20-1/2 20-1/2 20-1/2 20-1/2 19-3/4 19-3/4 20 19-3/4 20 22-1/2 26-3/4 27 19 21
COMMERCIAL GAS MASTER-FIT® BTR BOOSTER THE ELIMINATOR™ Self-Cleaning System • Designed to significantly reduce or eliminate buildup of lime, sand and other sediment inside the tank • Reduced sediment buildup helps Master-Fit water heaters maintain their rated energy efficiency and reduce water heating costs • Self-cleaning system also helps prolong tank life Built-in Induced Draft Blower • Produces power-induced draft of makeup air prior to burner ignition • Provides more efficient control of heat through
1-1/2" NPI OUTLET 1" NPI RELIEF VALVE OPENING H 15.2cm A B D C E G F 1.5 3.8cm 1-1/2" NPI INLET Model Number CLEARANCE Gallon Capacity BTU Input Per Hour Recovery Capacity GPH @ 100°F Rise BTR-151 32 150,000 145 BTR-201 32 199,900 194 Dimensions in Inches Model Number BTR-151 & BTR-201 A B C D E 45 40 27-3/4 32-1/4 15-3/4 F G H 5 6-1/2 6 Approx. Shipping Weight (lbs) STD/ ASME 460/440 Specify when ordering propane (LP) gas.
COMMERCIAL GAS MASTER-FIT® ULTRA-LOW NOx 80% Thermal Efficiency means Lower Operating Costs Fan Assisted Combustion • The blower is built into the low NOx burner assembly • Complies with California SCAQMD Rule 1146.
Model Number BTL-120 BTL-154 BTL-180 BTL-198 BTL-199 BTL-250 BTL-275 BTL-310 BTL-366 BTL-400 BTL-250A BTL-275A BTL-310A BTL-366A BTL-400A Gallon Capacity Input BTU/HR Recovery Capacity GPH @ 100°F Rise 81 81 81 81 100 100 100 86 86 86 100 100 86 86 86 120,000 154,000 180,000 199,000 199,000 250,000 275,000 310,000 366,000 390,000 250,000 275,000 310,000 366,000 390,000 115 148 173 191 191 240 264 298 352 375 240 264 298 352 375 Electrical characteristics—120V-60 Hz A. C., 5.0A.
COMMERCIAL GAS MASTER-FIT® ULTRA-LOW NOx ROUGH IN DIMENSIONS: MASTER-FIT BTL 199 ULN (CONTINUED) F TOP OUTLET 1 1/2 NPT TOP INLET 1 1/2 NPT AC B H DH E TOP VIEW DIMENSIONS: MASTER-FIT BTL 199 ROUGH ULN IN DIMENSIONS: MASTER-FIT BTL 1 BACK V I F F OP OUTLET 1 1/2 NPT TOP INLET 1 1/2 NPT K TOP OUTLET 1 1/2 NPT AC B G L E TOP VIEW J FRONT VIEW 101 H DH TOP VIEW BACK VIEW B
Letter BTL-120, 154, 180, 198 BTL-199, 250(A), 275(A) BTL-310(A), 366(A), 400(A) Dimensions in Inches A B C D E F 63-3/4 37 65 52-3/4 20-3/4 21 G H I J 53 6 27-3/4 K L Approx. Shipping Weight (lbs) Standard ASME 71-3/4 37 73 60-3/4 20-1/2 21 3/4 NPT 61 6 27-3/4 1-1/2 NPT 1-1/2 NPT 71-3/4 37 73 60-3/4 20-1/2 21 61 6 27-3/4 BTL-120, 154, 180, 198 BTL-199, 250(A), 275(A) BTL-310(A), 366(A), 400(A) 650 N/A 750 800 810 860 Electrical characteristics—120V-60 Hz A. C., 5.0A.
COMMERCIAL GAS CONSERVATIONIST® BT Glasslined Tank • Maximizes tank life. • Fully Automatic Controls with Safety Shutoff • Accurate, dependable control system requires no electric connections. Fixed automatic gas shutoff device for added safety. Not recommended for 180°F sanitizing. Heavy Gauge Steel Jacket • Finished with baked enamel over bonderized undercoat. Foam Insulation • Saves fuel, helps reduce standby heat loss.
E *TEMPERATURE AND PRESSURE RELIEF VALVE COLD HOT H G B DRAIN VALVE *INSTALL IN ACCORDANCE WITH LOCAL CODES. ANODE ROD L GAS INLET F K K HOT WATER OUTLET COLD WATER INLET T&P VALVE *TEMPERATU AND PRESSU RELIEF VALV C G J B DRAIN VALVE DRAIN VALV A CL CL D M Gallon Capacity Input Rating BTU/HR Recovery Capacity GPH @ 100°F Rise Approx.
COMMERCIAL GAS CONSERVATIONIST® POWER VENT Approval Rating and Certification • All models comply with ANSI Z21.10.3/CSA 4.3 and ASHRAE/IES 90.1-2004 • Meets Texas and other low NOx areas requiring 40 ng/J • All models are approved for use in combined appliance applications.
ANODE D COLD HOT Ø Model Number Approx. Gallon Capacity Btuh Input Approx. Shipping Weight 75 76,000 277 lbs BTF-80 Model Number BTF-80 Model Number BTF-80 Dimensions in inches A B C D 70-5/8 61-1/4 26 33-1/8 Dimensions in inches E F G H 11 13-1/4 53 15-1/4 Recovery capacity based on 81% thermal efficiency. Available in LP (Propane) gas. Can be installed up to 10,100 feet without alteration.
COMMERCIAL GAS CONSERVATIONIST® POWER DIRECT VENT DynaClean™ Diffuser Dip Tube • Helps reduce lime and sediment buildup and maximizes hot water output. Made from longlasting PEX cross-linked polymer Blue Diamond® Glass Coating • Provides superior corrosion resistance compared to the industry-standard glasslining. Hot Surface Ignition • Has a solid state ignition surface that does not flutter or blow out • Provides increased reliability and efficiency over spark ignition systems.
D A B C A B G F Model Number E Approx. Gallon Capacity Btuh Input Approx. Shipping Weight (lbs) 75 72,000 277 BPD-80 Model Number BPD-80 H Dimensions in Inches A B 70-5/8 61-1/4 C D E F G H 26 33-1/8 11 13-1/4 53 15-1/4 Specify when ordering propane (LP) gas. Can be installed up to 10,100 feet without alteration. Recovery capacity based on 81% thermal efficiency.
COMMERCIAL GAS CONSERVATIONIST® ULTRA-LOW NOx Code Compliance • The Ultra-Low NOx atmospheric vent commercial gas water heater which meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and Current Edition ASHRAE/IES 90.1. Fully Automatic Controls with Safety Shutoff • Accurate, dependable control system requires no electric connections. Fixed automatic gas shutoff device for added safety. Not recommended for 180˚ F sanitizing.
TOP VIEW WATER ET H TEMPERATURE AND PRESSURE RELIEF VALVE C COLD HOT G B DRAIN VALVE K HOT WATER OUTLET L GAS INLET K COLD WATER INLET F J DRAIN VALVE D B A E M FRONT VIEW Gallon Capacity Input BTU/hr Recovery Capacity GPH @ 100°F Rise Approx.
COMMERCIAL GAS POWER BURNER LIGHT DUTY Power Gas Burner • Electronic flame safeguard control with direct spark ignition • Redundant gas valves for added safety • Power gas burner requires 120V, 60Hz service • Non-forced-draft burner; negative draft required in vent piping Fully Automatic Controls with Safety Shutoff • High temperature limit control (manual reset) • Dual thermostats for accurate temperature control Glass Coating • Exclusive process provides superior protection against corrosion 3-Year Li
D 19.00 H ROUGH IN DIMENSIONS - Models BTP-139(A) Thru BTP-370(A) 64.93" BAROMETRIC DRAFT CONTROL ASSEMBLY INLET & DIP TUBE OUTLET HI T’STAT OUTLET T&P G J A LO’ TSTAT INLET B CLEANOUT 34.75" INSPECTION POWER BURNER ASSEMBLY C 24.
COMMERCIAL GAS LOW NOx POWER BURNER Venting Options • BTP models designed for conventional atmospheric vertical venting. Barometric draft regulating damper provided. Order Vent Kit Part #100125540. • BTPV models designed for horizontal atmospheric sidewall venting or direct venting. • For sidewall venting order Vent Kit Part #100125500. • For direct venting order Vent Kit Part #100131270.
1-1/2" INLET & DIP TUBE 1-1/2" OUTLET I D 1-1/2" NPT OUTLET OPENING (FRONT & BACK) 1" NPT T&P VALVE OPENING G 1-1/2" NPT INLET OPENING (FRONT & BACK) E I H A B FLUE REDUCER SHIPPED W/VENT HOOD CLEANOUT OPENING 1-1/2" NPT OUTLET OPENING (FRONT & BACK) 1" NPT T&P VALVE OPENING C F 1-1/2" NPT INLET OPENING (FRONT & BACK) H A B CLEANOUT OPENING C F Model Number BTP(V)-540A BTP(V)-650A BTP(V)-740A Model Number BTP(V)-540A BTP(V)-650A BTP(V)-740A Dimensions in Inches A B C D E 80-3/4 80-3
COMMERCIAL GAS CONSERVATIONIST® HIGH VOLUME POWER BURNER Power Gas Burner • Suitable for natural or propane gas • Electronic flame safeguard control with intermittent spark ignition • Main and pilot automatic gas valves with gas pressure regulators • Diaphragm air switch for proof of blower operation • Flame inspection port • Low NOx available on models from 400,000 Btu to 2,000,000 BTU (Natural gas only) • Factory start=up included. Required for activating and assuring maximum performance.
Model Number BTP-150-140 BTP-150-199 BTP-150-255 BTP-150-270 BTP-150-400 BTP-150-540 BTP-150-720 BTP-200-300 BTP-200-600 BTP-200-800 BTP-200-1000 BTP-200-1250 BTP-200-1500 BTP-300-300 BTP-300-600 BTP-300-800 BTP-300-1000 BTP-300-1250 BTP-300-1500 BTP-400-600 BTP-400-800 BTP-400-1000 BTP-400-1250 BTP-400-1500 BTP-400-1750 BTP-400-2000 BTP-600-720 BTP-600-1000 BTP-600-1250 BTP-600-1500 BTP-600-1750 BTP-600-2000 BTP-600-2250 BTP-600-2500 Gallon Capacity Recovery Capacity GPH @ 100°F Rise Input BTU/ HR *Natu
COMMERCIAL GAS CONSERVATIONIST® HIGH VOLUME POWER BURNER (CONTINUED) Optional Low Nox Burners BTUH Available Low Nox Burner BTU Input Sizes (Nat.
Model Number Dimensions in Inches A B C G H J BTP-150-140 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 D E F 5 47 73-1/2 BTP-150-199 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 6 47 73-1/2 BTP-150-255 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 6 47 73-1/2 BTP-150-270 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 6 57-1/2 73-1/2 BTP-150-400 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 7 57-1/2 73-1/2 BTP-150-540 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 8 57-1/2 73-1/2 BTP-150-720 82-1/4 13-1/2 1-1/4
COMMERCIAL GAS CONSERVATIONIST® DURACLAD OIL-FIRED TANK-TYPE Efficient Combustion Chamber • Precast, high temperature combustion chamber made of alumina silica ceramic fiber. Engineered for maximum insulation and heat reflection. Unique design assures more complete combustion by stabilizing flame pattern.
Dimensions in Inches Model Number A B C D E COF-199† 74-1/2 36-3/4 27-3/4 2 3/4 NPT COF-245 74-1/2 36-3/4 27-3/4 2 3/4 NPT COF-315A 74-1/2 73-3/4 73-3/4 73-3/4 36-3/4 36-3/4 36-3/4 36-3/4 27-3/4 27-3/4 27-3/4 27-3/4 2 2 2 2 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT COF-385A COF-455A COF-700A Dimensions in Inches Model Number F G H J K L COF-199† 8 26-5/8 74-1/2 1-1/2 NPT 1-1/2 NPT 22-3/4 COF-245 8 26-5/8 74-1/2 1-1/2 NPT 1-1/2 NPT 22-3/4 COF-315A 8 8 8 8 26-5/8 74-1/2
COMMERCIAL GAS CUSTOM HEAVY-DUTY LARGE VOLUME OIL-FIRED Fully Automatic Controls with Safety Shutoff • High temperature limit control (manual reset). CSA Certified and ASME rated temperature and pressure relief valve. • Hinged door control compartment with key lock for ease of access. • Two thermostats, upper and lower, for accurate temperature control. Jacket and Insulation • Heavy gauge steel jacket with baked powder coat finish.
Model Number Gallon Capacity Input Rating BTU/HR Recovery Capacity GPH @ 100°F Rise COF-150-140 163 140,000 136 COF-150-199 163 199,000 193 COF-150-255 163 163 150 151 151 145 221 221 221 201 201 201 300 300 300 300 300 300 411 411 411 411 397 397 397 594 594 594 594 594 594 575 575 255,000 270,000 350,000 400,000 540,000 720,000 300,000 600,000 800,000 1,000,000 1,250,000 1,500,000 300,000 600,000 800,000 1,000,000 1,250,000 1,500,000 600,000 800,000 1,000,000 1,250,000 1,500,000 1,750,000 2,
COMMERCIAL GAS CUSTOM HEAVY-DUTY LARGE VOLUME OIL-FIRED CONTINUED) 123
Model Number Dimensions in Inches A B C G H J COF-150-140 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 D E F 5 47 73-1/2 COF-150-199 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 6 47 73-1/2 COF-150-255 82-1/4 13-1/2 1/2 29-1/4 1-1/4 36-1/2 6 47 73-1/2 COF-150-270 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 6 57-1/2 73-1/2 COBT-150-350 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 7 57-1/2 73-1/2 COF/COBT-150-400 82-1/4 13-1/2 1 29-1/4 1-1/4 36-1/2 7 57-1/2 73-1/2 COF/COBT-150-540 82-1/4 13-1/2 1
COMMERCIAL ELECTRIC LIGHT-SERVICE Designed for light duty commercial applications with intermittent hot water loads. Glasslined Tank • Tank interior is coated with glass specially designed by A. O. Smith for water heater use. Heating Elements • Two 4.5 KW zinc plated copper sheathed elements are standard. Standard Voltages • The standard voltage is 240V single phase.
ANODE JUNCTION BOX T&P VALVE T&P VALVE ACCESS PANEL ACCESS PANEL DRAIN VALVE Model Number LTE 66D LTE 80D LTE 120D Gallon Capacity Standard Element Wattage 240 VAC 66 80 119 4500 4500 4500 Dimensions in Inches A B 60-1/4 53 60-1/2 52-1/4 61-1/2 54-1/2 C D Diameter 22 24 28 8 8 8 Approx. Shipping Weight (lbs) 146 175 268 Not available with top mounted T&P valve option Element Wattage (Upper/Lower) U. S.
COMMERCIAL ELECTRIC DEN/DEL ELECTRIC DURA-POWER™ Glasslined Tank • Thirteen sizes, 6 thru 119 gallon capacity. • Tank interior is coated with glass specially designed by A. O. Smith for water heater use. Elements • Zinc plated copper sheaths for longer life. • Medium watt density means lower surface temperature to minimize scale build-up and more surface to heat water. Element sizes from 1.5 to 6 KW.
TOP VIEW DEL 6/10/15/20 OUTLET 3/4” (FEMALE) NPT HOT WATER OUTLET DEL-6 ALTERNATE OUTLET 3/4” (FEMALE) NPT 3/4” NPT RELIEF VALVE OPENING “B” ELECTRICAL CONNECTION “B” ELECTRICAL 2 1/2” CONNECTION (63.
COMMERCIAL ELECTRIC GOLD Xi SERIES Advanced Electronic Control • Plain English text and animated icons display diagnostics Economy Mode Operation Lowers the Operating Set Point and Reduces Operating Costs Thermostatic Linear Sequencing Control Helps Reduce Current Surges and Provides Accurate Control of Water Temperature Goldenrod Elements • All DVE models ship standard with patented Goldenrod 24K gold plated elements. Goldenrod elements provide long life with superior scaling resistance.
WATER OUTLET C CONDUIT OPENING 3/4” NPT OPENING A INLET OPENING DRAIN VALVE 5.25 B Model Number DVE-52 DVE-80 DVE-120 Dimensions in Inches Gallon Capacity A B C Approx. Shipping Weight (lbs) 50 80 119 55-3/4 60-1/4 62-1/4 21-3/4 25-1/2 29-1/2 27 31 35 265 280 390 See specification sheets or contact your local rep for optional kW’s available.
COMMERCIAL ELECTRIC GOLD SERIES Gold Elements • DRE models ship with the Goldenrod 24K gold plated elements (see spec sheet for kW options). • Patented Goldenrod elements provide long life and superior scaling resistance. • Low watt density means lower surface temperature to minimize scale buildup and more surface to heat water. Goldenrod elements carry a one-year warranty against failure due to lime scale buildup.
WATER OUTLET C CONDUIT OPENING 3/4” NPT OPENING A INLET OPENING DRAIN VALVE 5.25 B Model Number DRE-52* DRE-80 DRE-120 Dimensions in Inches Gallon Capacity A B C Approx. Shipping Weight (lbs) 50 80 119 55-3/4 60-1/4 62-1/4 21-3/4 25-1/2 29-1/2 27 31 35 265 280 390 * DRE-52 is maximum 36kW. See specification sheets or contact your local rep for optional kW’s available.
COMMERCIAL ELECTRIC HEAVY-DUTY CUSTOM Xi Advanced Electronic Control • Provides Precise Temperature Control and Plain English Text with Animated Icons Display L ow-Water Cutoff—Remote Electronic Immersion-Type Probe to Prevent Energizing of the Elements, Eliminating Accidental Dry Firing Incoloy-Sheath Heating Elements Standard Factory-Wired, 120V Circuit Controls Power-Circuit Fusing for System Protection Glass-Lined Tank, with ASME Construction SA Certified and ASME Rated T&P C Relief Valve BACnet an
Dimensions in Inches Model Gallon Maximum Number Capacity kW Input A B C D 5 10 20 30 40 50 65 80 100 120 20-1/4 26-1/4 27-1/4 35-3/4 45-3/4 54-3/4 50-1/2 49-1/4 58-1/4 63-1/4 16-1/4 18-3/4 20-1/2 20-1/2 20-1/2 20-1/2 26-1/2 28 28 30 22-1/2 25 26-1/2 26-1/2 26-1/2 26-1/2 33-1/2 35 35 37 5-1/4 5-1/4 5-3/4 5-3/4 5-3/4 5-3/4 7 7 7 7-1/2 DSE-5 DSE-10 DSE-20 DSE-30 DSE-40 DSE-50 DSE-65 DSE-80 DSE-100 DSE-120 3 6 18 24 36 90 90 90 90 90 Approx.
COMMERCIAL ELECTRIC HEAVY-DUTY CMC/SU BOOSTER ELECTRIC DURA-POWER™ Incoloy-Sheath Heating Elements Standard A. O.
SU MODELS CMC MODELS Dimensions in Inches Model Number Gallon Capacity A B SU MODELS C Inlet/ Outlet Approx. Shipping Weight (lbs) CMC-6 through CMC-18 5 13.75 13 23.5 3/4 80 CMC-20 through CMC-54 5 12 18 23.5 3/4 96 SU-24 through SU-54 20 25 22.
COMMERCIAL ELECTRIC HEAVY-DUTY PREMIUM ELECTRIC DVE/DHE DURA-POWER™ Advanced Electronic Control: A. O. Smith’s New Propriety Electronic Water Heater Control Provides Precise + or - 1ºF Temperature Control that is Ideal for Industrial and Food Service Applications where Exact Temperatures of Hot Water are Needed. iCOMM™ Compatible and Can be Monitored from Remote Locations; Call 1.888.WATER02 for More Information.
Recovery Capacity Standard Number of BTU Input Immersion GPH @ kW and Output 100°F Ratings Heaters Rise Recovery Standard Number of Capacity BTU Input kW Immersion GPH @ and Output Ratings Heaters 100°F Rise 24 2-12kW 81,912 98 600 40-15kW 2,047,800 2,460 30 2-15kW 102,390 123 630 42-15kW 2,150,190 2,583 36 3-12kW 122,868 147 660 44-15kW 2,252,580 2,706 45 3-15kW 153,585 184 690 46-15kW 2,345,970 2,829 60 4-15kW 204,720 246 720 48-15kW 2,457,360 2,952 75 5-15kW 255,975
COMMERCIAL ELECTRIC HEAVY-DUTY PREMIUM ELECTRIC DVE/DHE DURA-POWER™(CONTINUED) 139
Model Number Nominal Gallon Capacity Dimensions in Inches A B C D E 77 91 81 93 100 94 109 121 111 111 138 150 177 211 296 317 345 36 36 42 42 42 48 48 48 54 60 60 60 66 72 78 90 102 10-1/2 17-1/2 10-1/2 24 8-1/4 17 8-1/4 23 8-1/4 26-1/2 14 24 14 32 14 38 16-1/2 32 16-1/2 29-1/2 16-1/2 43 16-1/2 50 20 60 20 72-1/2 20-1/2 113-1/2 20-1/2 121 22 132 30 30 36 36 36 42 42 42 48 48 48 56 60 60 60 66 72 78 90 102 37 37 43 43 43 49 49 49 55 55 55 61 67 67 67 73 79 85 97 109 16 16 17-1/2 17-1/2 17-1/2 19
CIRCULATING WATER HEATER XP HIGH EFFICIENCY WATER HEATERS Up to 96% Thermal Efficiency Fully Modulating with 5:1 Turndown Advanced Electronics with Large Touchscreen Display and Built-In Lead/ Lag Sequencing Direct Vent Flexibility Up to 100 Feet Matches with Storage Tank for Storage Flexibility ASME Rated Relief Valve 160 lb.
Recovery Capacities BTU/HR Natural Gas Input Water Flow XWH-150 150,000 XWH-200 200,000 XWH-285 XWH-400 Model Number Temperature Rise 70 100 140 GPH 248 173 124 GPH 336 235 168 285,000 GPH 474 332 237 400,000 GPH 665 465 332 XWH-500 500,000 GPH 831 582 416 XWH-600 600,000 GPH 997 698 499 XWH-700 700,000 GPH 1,164 815 582 XWH-800 800,000 GPH 1,330 931 665 Line drawings and dimensions on the following page.
CIRCULATING WATER HEATER UNIT A XP HIGH EFFICIENCY XWH150 32.65" XWH200 32.65" WATER HEATERS (CONTINUED) XWH285 41.93" XWH400 XWH500 XWH600 XWH700 XWH800 41.93" 41.93" 41.93" 41.93" 41.93" B 18.25" 22.22" 20.07" 27.25" 31.72" 46.47" 40.47" 45.47" C 15.57" 15.57" 15.57" 15.57" 15.57" 15.57" 15.57" 15.57" D 6.68" 6.68" 9.18" 9.09" 9.19" 9.19" 9.19" 9.
285 - 800 UNIT XWH150 XWH200 XWH285 XWH400 F XWH500 XWH600 XWH700 XWH800 A 32.65" 32.65" 41.93" 41.93" 41.93" 41.93" 41.93" 41.93" E B 18.25" 22.22" 20.07" 27.25" 31.72" 46.47" 40.47" 45.47" C 15.57" 15.57" 15.57" 15.57" 15.57" 15.57" 15.57" 15.57" D E 6.68" 15.81" 6.68" 15.81" 9.18" A 19.16" 9.09" 19.07" 9.19" 19.07" 9.19" 19.17" 9.19" 19.17" 9.19" 19.17" F 21.62" 21.62" 34.27" 34.19" 32.87" 36.45" 36.45" 36.45" G 11.59" 11.59" 14.00" 14.00" 14.00" 14.00" 14.00" 14.00" H 23.27" 23.27" 31.45" 34.
CIRCULATING WATER HEATER XP PLUS HIGH EFFICIENCY WATER HEATERS Up to 99% in Low Temperature Applications Super Alloy Metal Fiber Burners 20:1 Turndown Models 2 Million BTUH and up, 10:1 Turndown Models 1.7 Million BTUH and Down ASME Rated Relief Valve 160 lb. ASME Working Pressure Factory-Installed Bronze Circulating Pump Adjustable Pump Delay Honeywell Sola Control with Color Touchscreen LCD Display Multi-Burner Sequencing Models 2 Million BTUH and up Have 4 Burners; Models 1.
Recovery Capacities Model Number XWH-1000 XWH-1300 XWH-1700 XWH-2000 XWH-2600 XWH-3400 BTU/HR Natural Gas Input Water Flow 920,000 1,300,000 1,700,000 2,000,000 2,600,000 3,400,000 GPH GPH GPH GPH GPH GPH Temperature Rise °F 100 1,065 1,497 1,962 2,317 3,000 3,956 Simple Heat Exchanger Model Dimensions Models XWH-1000 XWH-1300 XWH-1700 Dimensions in Inches Flue Outlet Diameter 6 8 8 Air Intake Diameter 6 6 8 49 68 29 38 23 9 34 45 6 11 11 2-1/2 inch NPT 2-1/2 inch NPT 2 inch NPT 57 76 2
CIRCULATING WATER HEATER XP PLUS HIGH EFFICIENCY WATER HEATERS (CONTINUED) 147
Recovery Capacities Model Number BTU/HR Natural Gas Input Recovery Capacity GPH @ 100°F Rise Approx.
COMMERCIAL WATER HEATER BURKAY® GENESIS® DOMESTIC WATER HEATER 85% Thermal Efficiency E lectronic Control with Precise Temperature Management Stage Gas Firing System - Prevents Short Cycling and Ensures Smooth Operation, Saves Fuel and Extends Product Life Low NOx Operation Copper Finned-Tube Heat Exchanger Space-Saving Design: Optional Stack Rack Allows One Unit to be Stacked on Top of Another, Doubling Output within the Footprint of a Single Unit ® Meets ASHRAE/IES 90.
F GAS CO NN ECTION G F EXHAUST VENT EXHAUST VENT G GAS CO NN ECTION INLET INLET OUTLET OUTLET H H E E D DR AIN DR AIN J J K K L L GWH-400 THRU GWH-750 GWH-1000 THRU GWH-2100 F AIR INLET B GAS CO NN ECTION G INLET OUTLET SIDE VIEW A E C D DR AIN J SIDE VIEW Model Number GWH-400N GWH-500N GWH-650N GWH-750N GWH-1000N GWH-1250N GWH-1450N GWH-1800N GWH-2100N Model Number GWH-400N GWH-500N GWH-650N GWH-750N GWH-1000N GWH-1250N GWH-1450N GWH-1800N GWH-2100N K L GWH-400 THRU GWH
COMMERCIAL WATER HEATER VARIABLE FIRE™ HIGH-EFFICIENCY WATER HEATERS Up to 87% Thermal Efficiency Advanced Modulating Control with Venturi-Mixing Gas/Air Ratio System Small Footprints, Zero Clearance to Combustibles on Sides of Unit Category II and IV Listed: Requires the use of AL29-4C, a Vent Material That Resists the Effects of Corrosive Condensates Complies with SCAQMD Rule 1146.
FF FF GAS GAS CO CONN NNECTION ECTION GG GAS GAS CO CONN NNECTION ECTION AIR AIR INLET INLET GG AIR AIR INLET INLET INLET INLET HH HH INLET INLET OUTLET OUTLET OUTLET OUTLET EXHAUST EXHAUST VENT VENT EE EE KK KK JJ LL DR DRAINS AINS (3/4 (3/4""NPT) NPT) CC JJ DR DRAINS AINS (3/4" (3/4"NPT) NPT) MM NN D1 D1 D2 D2 PP PP REAR REARVIEW VIEW REAR REARVIEW VIEW REAR REAR VIEW VIEW (VWH0500N-VWH1000N) (VWH0500N-VWH1000N) pped ippedloose loose EXHAUST EXHAUST VENT VENT LL MM NN REAR REARV
COMMERCIAL WATER HEATER BURKAY® ENERGY SAVER COPPER HEAT EXCHANGER All Non-Ferrous Waterways • Rustproof because water comes in contact with nothing but copper, brass or bronze • Copper transfers heat eight times faster than ferrous metals yet offer remarkable structural strength without excessive weight • Free from the effects of thermal shock Efficiency Copper Coil Combustion Chamber • Continuous coils of tightly wound copper tubing form a unique combustion chamber • Water circulating thru the coils, ar
H L WATER OUTLET A B D C M WATER INLET F E W J G K M WATER INLET Models HWH-120 A 49-3/8 30-3/8 23-5/8 20-3/4 5-1/2 10 11-13/16 6 26-11/16 20-3/4 1-1/4 NPT 1 NPT 1/2 NPT 1-3/4 120 lbs.
HOT WATER SUPPLY BOILERS BURKAY® HWH GAS DOMESTIC WATER HEATERS & BOILERS All Non-Ferrous Waterways • All castings are made of bronze or brass • All water tubes are made from copper • Brazed joints or flare union construction make the boiler immune to the effects of thermal shock and thermal cycling • A great boiler for domestic hot water supply Efficiency Copper Coil Combustion Chamber • The combustion chamber is a heat exchanger formed from a two passage coil of tightly wound continuous copper tube • Wa
E G J F EXTRA OPENING FOR THERMOMETER AND PRESSURE RELIEF VALVE HW-520 AND H HW-670 HW-300 P F S K M OUTLET NPT LOCATION OF MANUAL MAIN SHUTOFF VALVE OUTSIDE JACKET WHEN CODE REQUIRE (NOT SUPPLIED) A D B N GAS INLET (MALE) NPT C T L INLET NPT E G J EXTRA OPENING FOR THERMOMETER AND PRESSURE Dimensions in Inches T RELIEF VALVE HW-520 AND H HW-670 A B Models HW-300 HW-399 HW-420 HW-520 65 57-1/8 57-1/8 68-5/16 68-5/16 45-1/8 45-1/8 56-1/4 56-1/4 38-3/4 38-3/4 46 46 Overal
COMMERCIAL ELECTRIC BOILERS DURA-POWER™ NW ELECTRIC BOILERS ASME Code Construction Incoloy Immersion Heaters Control and Power Circuit Fusing Pilot Switch and Light eavy-Duty UL-Rated Magnetic H Contactors Rated for 100,000 Low-Water Cutoff 120V Control Circuit Modulating Step Control Hydronic Boiler, Not for Potable Water Applications 1-Year Limited Tank Warranty • For complete warranty information, consult written warranty or go to hotwater.com.
UL MINIMUM CLEARANCE REQUIRMENTS: 24” ALL SIDES, 12” TOP NOTE: ALLOW 30” CLEARANCE FOR HINGED CONTROL COMPARTMENT DOORS. ELEMENTS CAN BE CHANGED WITH 24” CLEARANCE. AN ADDITIONAL CONTROL PANEL IS REQUIRED ON UNITS ABOVE 500kW RATED AT 208 OR 240 VOLTS.
COMMERCIAL ELECTRIC BOILERS DURA-POWER™ NW ELECTRIC BOILERS (CONTINUED) Model Number NW-37-45-K NW-37-60-K NW-37-75-K NW-37-90-K NW-37-105-K NW-37-120-K NW-37-150-K NW-37-180-K NW-60-210-K NW-60-240-K NW-60-270-K NW-60-300-K NW-96-330-K NW-96-360-K NW-96-390-K NW-96-420-K NW-96-450-K NW-96-480-K NW-150-540-K NW-150-600-K NW-150-660-K NW-150-720-K NW-220-780-K NW-220-840-K NW-220-900-K NW-220-960-K NW-220-1020-K NW-220-1080-K NW-220-1140-K NW-334-1200-K NW-334-1260-K NW-334-1380-K NW-334-1500-K NW-334-1620-
1 1 1 3 4 4 5 5 5 5 5 5 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 15 15 15 15 15 15 15 18 18 18 19 18 18 18 18 18 1 @ 45 1@ 60 1 @ 75 3 @ 30 3 @ 30 +1 @15 4 @ 30 5 @ 30 4 @ 30 + 1@ 60 3 @ 30 + 2 @ 60 2 @ 30 + 3 @ 60 1 @ 30 + 4 @ 60 5 @ 60 9 @ 30 + 1 @ 60 8 @ 30 + 2 @ 60 7 @ 30 +3 @60 6 @ 30 + 4 @ 60 5 @ 30 + 5 @ 60 4 @ 30 + 6 @ 60 2 @ 30 + 8 @ 60 10 @ 60 8 @ 60 + 2 @ 90 6 @ 60 + 4 @90 4 @ 60 + 6 @ 90 9 @ 90 + 1 @ 30 10 @ 90 8 @ 90 + 2 @ 120 6 @ 90 + 4 @ 120 4 @ 90 + 6 @ 120 2 @ 90 + 8
HOT WATER GENERATOR STEAM OR BOILER HOT WATER HWG GENERATOR SYSTEMS All HWG Systems are Fiberglass Insulated and Jacketed Integral Bronze Circulator Pump oth Steam and Boiler Water Units B are Custom Built to Meet Your Specifications and are Completely Assembled with Components Sized, Piped, and Checked Before Shipping ASME Rated Cathodic Protection Custom Sizes Available up to 12,000 Gallons Available in Vertical or Horizontal Models 5 -Year Limited Tank Warranty and 1-Year Limited Coil Warranty • For
Dimensions in Inches Model Gal A B C D E HWG48-1000V 140 200 350 400 500 750 1000 89 85 102 107 86 118 150 30 36 42 42 54 54 54 22 24 25-1/2 25-1/2 30 30 30 11-1/4 15-1/2 19 19 25-1/2 25-1/2 25-1/2 2-1/2 2-1/2 2-1/2 2-1/2 3 3 3 Model Gal A B C D E F 200 350 400 500 750 1000 77 93 99 79 111 143 41 47 47 59 59 59 16 16 17 23 23 23 26 30 30 42 42 42 2-1/2 2-1/2 2-1/2 3 3 3 36 42 42 54 54 54 HWG24-140V HWG30-200V HWG36-350V HWG36-400V HWG48-500V HWG48-750V Dimensions in Inches HWG3
COMMERCIAL STORAGE TANKS STANDARD JACKETED STORAGE TANKS Glasslined Tank • Alkaline borosilicate composition permanently fused to steel by firing at a temperature of 1600°F, providing years of corrosion protection and dependable use. Ideal for Use with Gas Fired Copper Heat Exchanger Equipment for Potable Water at Temperatures Up to 180°F Threaded Openings • All tanks furnished with threaded openings for thermometer, relief valve, 2” recirculation lines, tank stat, and drain valve.
TJ-80A 3/4" NPT (ANODE ) TJ-80A ME INSPECTION ING (PLUGGED) 2" NPT REAR 2" NPT FRONT & REAR 2" NPT FRONT & REAR ASME PLATE UNDER COVE R ASME PLATE UNDER COVE R 3/4" 42 3/4" 32 1/4" 3/4" NPT REAR 3/4" NPT FRONT 3/4" NPT FRONT 2" NPT FRONT & REAR 2" NPT FRONT & REAR 51 7/8" 16" 2" ASME INSPECTION 2" ASME INSPECTION 3/4" NPT 7" OPENING (PLUGGED) OPENING (PLUGGED) REAR 3 3/4" 2" NPT 3/4" NPT (ANODE ) 3/4" NPT (ANODE ) 7" 3 3/4" 3 3/4" 3/4" NPT REAR TJ-80A TJV-120A 3/4" NPT REAR 1" NP
COMMERCIAL STORAGE TANKS CUSTOM-LINE FACTORY JACKETED & INSULATED STORAGE TANKS Standard Sizes • From 140 to 1,000 gallons. all stock tanks glasslined. Horizontal or Vertical Mounting Options Available High-Density, Fiberglass Insulated Jackets Meet R12.5 Minimum Thermal Insulation Requirements of the U.S. Department of Energy and Current Edition of ASHRAE/IES 90.1 ASME Construction • Available in 100, 125, 150 and 160 working pressures; 125 standard.
G G I* E I D A 3/4" 1" G I* G G B C F H *Note: These connections are not for piping connections. They are the anode locations and also serve as the required ASME 2” inspection openings. H STORAGE TANK SELECTION E-NPT E-NPT I* I* 1" NPT 3/4" NPT D B D I E-NPT E-NPT E-NPT A G 3/4" NPT F J 2" PLUG E H *Note: These connections are not for piping connections. They are the anode locations and also serve as the required ASME 2” inspection openings.
COMMERCIAL STORAGE TANKS UNINSULATED STANDARD STOCK BARE STORAGE TANKS Glasslined per ASME, HLW Procedures Horizontal or Vertical Mounting Options Available High-Density, Fiberglass Insulated Jackets or Bare Steel Tanks Cement or Epoxy Linings Available ASME Construction Magnesium Anodes Protect Against Corrosion. Meets R12.5 Minimum Thermal Insulation Requirements of the U.S. Department of Energy and Current Edition of ASHRAE/IES 90.
Model Number T-80 STD T-120 STD T-200 STD T-350 STD T-140 ASME T-200 ASME T-250 ASME T-325 ASME T-350 ASME T-400 ASME TN-500 ASME T-500 ASME T-750 ASME T-1000 ASME Model Number T-80 STD T-120 STD T-200 STD T-350 STD T-140 ASME T-200 ASME T-250 ASME T-325 ASME T-350 ASME T-400 ASME TN-500 ASME T-500 ASME T-750 ASME T-1000 ASME Model Number T-80 STD T-120 STD T-200 STD T-350 STD T-140 ASME T-200 ASME T-250 ASME T-325 ASME T-350 ASME T-400 ASME TN-500 ASME T-500 ASME T-750 ASME T-1000 ASME Gallon Capacity Ov
COMMERCIAL STORAGE TANKS HEAVY-DUTY LARGE VOLUME STORAGE TANKS MODEL HD CUSTOM-BUILT Custom-Built Tanks From 80 to 12,500 Gallons. Horizontal or Vertical Mounting Options Available High-Density, Fiberglass Insulated Jackets or Bare Steel Tanks Glasslined, Cement or Epoxy Linings Available ASME Construction • Available in 125, 150 and 160 psi working pressure.
Model Number HD20-80 HD20-100 HD24-125 HD24-140 HD24-175 HD30-175 HD30-200 HD30-250 HD30-300 HD36-250 HD36-300 HD36-350 HD36-400 HD36-500 HD42-375 HD42-450 HD42-500 HD42-600 HD42-700 HD42-800 HD48-500 HD48-600 HD48-700 HD48-750 HD48-900 HD48-1000 HD48-1250 HD48-1500 HD54-650 HD54-750 HD54-900 HD54-1000 HD54-1250 HD54-1500 HD54-1800 HD60-800 HD60-1000 HD60-1250 HD60-1500 HD60-1750 Shipping Weight (lbs.) Nominal Gallon Capacity Dimensions Diameter x O.A.
COMMERCIAL STORAGE TANKS HEAVY-DUTY LARGE VOLUME STORAGE TANKS MODEL HD CUSTOM-BUILT (CONTINUED) Model Number HD60-2000 HD66-1000 HD66-1500 HD66-2000 HD66-2500 HD72-2500 HD72-3000 HD72-3500 HD72-4000 HD84-4000 HD84-5000 HD84-6000 HD84-8000 HD96-7500 HD96-10000 HD96-12500 171 Shipping Weight (lbs) Nominal Gallon Capacity Dimensions Diameter x OAL (Inches) Black Steel Glasslined Epoxy Cement 2,000 1,000 1,500 2,000 2,500 2500 3,000 3,500 4,000 4,000 5,000 6,000 8,000 7,500 10,000 12,500 60 x 165 66
CUSTOM-LINE STORAGE TANKS (20” THRU 96” DIA. TANKS) OVERALL A B E THREADED LEG SOCKET "C" A A ASME PLATE A A A A A B B A A A A NOTE: 1) 54” DIAMETER AND LARGER TANKS MUST BE ORDERED WITH ANGLE LEGS RATHER THAN THREADED LEG SOCKETS FOR VERTICAL INSTALLATIONS. 2) SPECIFY FOR HORIZONTAL OR VERTICAL INSTALLATION. 3) NO LEG SOCKETS PROVIDED ON HORIZONTAL TANKS. 2 each 2” ASME inspection openings are standard on tanks 36” diameter and below.
COMMERCIAL WATER HEATER AC-U-TEMP COMPLETE HOT WATER SYSTEMS Standard Tank Sizes from 80 to 1000 Gallons Ac-U-Temp System Eliminates Costly Field Errors Simplifies Installation Standard Ac-U-Tanks are Factory Jacketed and Insulated All Systems are Built to Order Multi-Heater Systems for 50%100% Back-Up Superior I-Beam Skid Factory Hydrostatic and Fire-Tested Before Shipping ASME Relief Valve 125# Tank Temperature Sensor Tank Thermometer Isolation Valves Custom Tank Sizes to 10,000 Gallons 5-Year Limited He
INSTANTANEOUS SEMI-INSTANTANEOUS HWI WATER HEATERS A. O. Smith’s HWI Models are Available for Operation with Steam or Boiler Water as the Energy Source.; They are Factory Assembled with Components Sized, Piped and Checked at the Factory Before Shipment; HWI Models are All Space Saving Vertical Models. Code Listing: The System Will Employ an ASME ”U” Code Shell; Fitted with an ASME “U” Code 3/4” Diameter Copper Tube Heat Exchanger.
CONSULT THE XPERT. Confidently select the right water heater for your floor plans with the help of an Xpert. With just a few quick questions, the Xpert Product Selection Tool evaluates A. O. Smith’s full range of product options against your installation, energy efficiency and usage requirements. The result is a custom selection of water heaters recommended just for you. Visit hotwater.com/Xpert to consult the Xpert or download the A. O. Smith App.