Energy Guide

Page 100 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
TABLE: Input Test
P
Input deviation of/at: P rated (W) P measured (W) P Required P Remark
120V~, 60Hz 130 106.8 -17.8% +10% P
Supplementary information: N/A
4.5 TABLE: Temperature Test
P
Test voltage (V) ...................................
120V~/60Hz
 
 
Ambient (C) ........................................
24.1
 
 
Maximum temperature T of part/at: T (°C) allowed T
max
(°C)
Power wire
55.2
 
80
PCB
64.3
 
95
Metal enclosure
46.6
 
Ref.
Motor winding
96.4
 
110
Supplementary information:
The temperatures were measured under worst case normal mode defined in 1.2.2.1 and as described in
sub-clause 1.6.2 and at voltages as described above.
With a rated maximum ambient temperature of 25°C.
For the components temperatures limit, please refer to table 1.5.1.
TABLE: Dielectric Voltage Withstand Test
P
Test voltage applied between: Test potential applied
(V)
Breakdown / flashover
(Yes/No)
Basic insulation 1000V No