UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
12.2
Cord-connected wall-mounted appliances
P
12.2.1
Mounting brackets and any necessary hardware
required to install a cord-connected, wall
surface-mounted appliance shall be provided with
the appliance or shall be available from the
appliance manufacturer.
P
12.2.2
With reference to 12.2.1, means shall be provided
to reduce the likelihood that an appliance is
dislodged from the wall. When the construction of
the appliance or the mounting means permits the
bottom
P
12.2.3
An opening provided for hanging or mounting an
appliance shall be located or guarded so that a
nail, hook, or the like does not displace a part that
creates a risk of fire, electric shock, or injury to
persons and does not contact one of the following:
P
a)An uninsulated live part;
P
b)Film-coated wire;
P
c)Internal wiring; or
P
d)Moving parts.
P
13
Protection Against Corrosion
P
13.1 Iron and steel parts shall be protected against
corrosion by enameling, galvanizing, plating, or an
equivalent means.
P
14 Power Supply Connections – Permanently-
Connected Appliances
P
14.1
General
P
14.1.1
An appliance intended for permanent connection to
the power supply shall be constructed so that it
may be permanently connected electrically to one
of the wiring systems that is acceptable for the
appliance in accordance with the National
Electrical Code, ANSI/NFPA 70.
P
14.1.2
With reference to the requirement specified in
14.1.1, the following types of appliances shall be
provided with means for permanent electrical
connection to the power supply:
P
a)An attic fan;
P
b)An appliance intended for permanent attachment
to a building structure;
P
c)A duct-connected appliance; or
N/A
d)A range hood.
N/A