Energy Guide
Page 16 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
14.1.3
Power supply terminal or leads identified for
connection to Class 2 wiring shall comply with
Class 2 circuit requirements, 31.3.
P
14.2 Knockouts and openings P
14.2.1 A knockout in a sheet-metal enclosure provided for connection of the appliance to
a wiring system installed in accordance with the National Electrical Code,
ANSI/NFPA 70, shall be securely attached and removable without deformation
that would impair the intended performance of the enclosure. The thickness of the
knockout shall be in accordance with the thicknesses specified in Table 7.1.
P
14.2.2
There shall be a flat surface surrounding a
knockout or opening of sufficient area to permit the
attachment of a length of standard rigid metallic
conduit of a size corresponding to the size of the
knockout or opening. The flat area shall have a
minimum diameter in accordance with Table 14.1.
P
14.2.3
A knockout or opening shall be surrounded on
both the inside and outside surfaces by a flat
surface to permit proper installation of a locknut.
The flat surface shall extend in all directions
beyond the edge of the knockout for a distance
not less than that specified in Table 14.1.
P
14.3 Field-wiring compartments P
14.3.1 A field-wiring compartment in which power-supply
connections are made shall be located so that the
connections are able to be readily inspected after
the appliance is installed as intended.
P
14.3.2 Accessibility of field-installed wiring and inspection
of splices is to be judged by:
P
a)A trial installation following any instructions
provided by the manufacturer; or
P
b)Using any wiring system permitted by the
National Electrical Code, ANSI/NFPA 70, if no
instructions are provided.
P
14.3.3
The minimum usable volume of an outlet box or
terminal compartment in which field-installed wiring
connections to the power supply are to be made
shall be as specified in Table 14.2.
N/A
14.3.5 An electrical component shall not be mounted on a
part, such as the cover of a wiring-terminal
compartment, that is removed to permit field-wiring
connections or inspections.
P
14.3.6 A field-wiring compartment intended for connection
of a supply raceway and mounted integrally with the
appliance shall be attached so as to be prevented
from turning with respect to the appliance.
P