UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
14.4.9
The free length of a lead inside an outlet box or
wiring compartment shall be 152.4 mm (6 inches) or
more when the lead is intended for field connection
to an external circuit.
P
14.4.10
A screw used to secure an equipment grounding
lead to an enclosure shall engage at least two full
threads in the metal, which is not prohibited from
being extruded to provide the threads.
P
14.5
Identification
P
14.5.1 A permanently connected appliance rated 125 volts
or 125/250 volts (3-wire) or less, and employing a
lamp- or element-holder of the Edison screw-
shell type, or a single-pole switch or
overcurrent-protective device other than an
automatic control without a marked "off" position
shall have element-holder but to which shall not be
connected a single-pole switch or single-pole
overcurrent- protective device, other than an
automatic control without a marked "off" position.
P
14.5.2 With reference to 14.5.1, if leads from the motor or
other component terminate in an attachment plug
intended for insertion in a receptacle that is:
P
a)Provided as part of the appliance; and
P
b)Intended for connection of the branch-circuit
power-supply conductors.
P
14.5.3
A terminal intended for connection of a grounded
power-supply conductor shall be made of or plated
with metal substantially white in color and shall be
readily distinguishable from the other terminals; or
identification of that terminal shall be clearly shown
in some other manner, such as on an attached
wiring diagram.
P
14.5.4
The surface of a lead intended for the connection
of a grounded power-supply conductor shall have a
white or gray color and shall be readily
distinguishable from the other leads.
P
14.5.5
The surface of a lead intended for connection of an
equipment-grounding conductor shall be green with
or without one or more yellow stripes, and no other
lead shall be so identified.
P
14.5.6A terminal intended for the connection of an
equipment-grounding conductor shall be identified
by:
P
a)Use of a wire-binding screw with a green-colored
head that is slotted or hexagonal, or both;
P
b)Use of a threaded stud with a green-colored
hexagonal nut;
P
c)Use of a green-colored pressure-terminal
connector;
P