UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
19.3 The internal wiring and connections of an
appliance shall consist of components of a type or
types that are acceptable for the particular
application, when considered with respect to:
a)The temperature and voltage to which they are
likely to be subjected;
b)Exposure to oil, grease, or moisture; and
c)To other conditions of service to which they are
likely to be subjected.
P
19.4 Wiring shall be protected from sharp edges
including male screw threads, burrs, moving parts,
and other agents that might cause abrasion of the
insulation on conductors.
P
19.5 A flexible cord used for external interconnection as
mentioned in 19.1 shall be provided with bushings
and strain relief that comply with Section 54, Strain
Relief Test.
P
19.6 Insulated conductors that pass through an opening
in a sheet-metal wall that is not more than 1.07 mm
(0.042 inch) thick shall be:
a)Securely held away from the edges of the
opening;
b)Protected by a bushing, metal grommet, eyelet,
or the equivalent; or
c)Protected by rolling the edge of the metal
opening at least 120 degrees.
P
19.7 A non-metallic bushing as mentioned in 19.6(b)
shall:
a)Be securely held in place; and
b)Have a minimum wall thickness of 1.2 mm (3/64
inch).
P