Energy Guide

Page 34 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
23.6 When the running heating test is conducted with
the motor installed within the appliance, testing
shall be repeated under any operating condition
that may reduce the cooling effect to the motor
under test. Operating conditions include, but are
not limited to, the type of impeller, variations in the
impeller (such as number of blades, pitch, length)
and enclosure variations (such as reduced
volume/area, location and size of baffles).
N/A
24 Protective Devices P
24.1 A protective device, the intended functioning of
which requires replacement or resetting, shall be in
a readily accessible location
P
24.2
A protective device shall be inaccessible from
outside the appliance without opening a door or
cover.
P
24.3 A door or cover of an enclosure shall be hinged or
attached in an equivalent manner when it gives
access to any overload-protective device, the
intended functioning of which requires renewal, or
if it is necessary to open the cover in connection
with the intended operation of the protective
device.
P
24.4 A protective device shall not open the circuit during
intended operation of the appliance.
P
24.5 In an automatic appliance, when breakdown of a
capacitor that is not part of a permanent-split-
capacitor motor or a part of a capacitor-start motor
results in a risk of fire or electric shock, thermal or
overcurrent protection shall be provided in the
appliance.
P
25 Fuseholders and Fused Attachment Plugs N/A
25.1 In addition to the applicable requirements in this
standard, a fuseholder located in the enclosure of a
unit shall comply with the Standard for Fuseholders
– Part 1: General Requirements, UL 4248-1, and
the applicable Part 2 (e. g. UL 4248-9), and a fused
attachment plug shall comply with the Standard for
Attachment Plugs and Receptacles, UL 498, or the
Standard for Cord Sets and Power-Supply Cords,
UL 817.
N/A