UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
26.4 The overload protection specified in 26.1 – 26.3 is
not required to be provided as part of the unit when
all of the following conditions exist:
a)The motor is to be field-wired to a separate circuit
that does not supply any other loads within the unit;
b)The motor overload protection is part of a
separate, field-provided motor controller that does
not require wiring interconnection to the unit,
except for the motor circuit; and
c)The product is marked in accordance with 80.2.6.
P
26.5 Fuses shall not be used as motor-overload
protective devices unless the motor is protected by
the fuse of the highest current rating that can be
inserted in the fuseholder.
P
27 Switches, Including Motor Controllers N/A
27.1 A switch or other control device shall:
a)Be acceptable for the application;
Exception: A switch or other device that controls a
motor that has not been previously investigated for
its suitability of controlling a motor shall be
subjected to the Tests of Switches and Controls,
Section 59.
b)Have a current and voltage rating not less than
that of the load that it controls; and
c)Be located within the confines of the frame or
enclosure of the appliance or be additionally
protected so as to reduce the likelihood of contact
by external objects.
N/A