Page 42 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
30.4 In the application of 30.2, 47.1, and Table 30.2 to
an appliance employing a motor not rated in watts,
Tables 430.147 through 430.150 of the National
Electrical Code, ANSI/NFPA 70, are to be used as
applicable to determine the relationships between
watts and full-load current for motors.
N/A
30.5 At terminal screws and studs to which connections
are made in the field by wire connectors, eyelets,
or the like described in 14.4.1, spacings shall not
be less than those specified in Table 30.2 with the
connectors, eyelets, or the like, in such position
that minimum spacings – opposite polarity and to
dead metal – exist.
P
30.6 A barrier or liner of vulcanized fiber or similar
material employed in lieu of spacings shall be of a
material acceptable for the application and shall
not be less than 0.8 mm (1/32 inch) thick.
P
30.7 Motor spacings shall comply with the spacing
requirements in the Standard for Rotating Electrical
Machines – General Requirements, UL 1004-1.
P
30.8 Spacings on a printed wiring board assembly that
are less than indicated in Table 30.2:
a)Shall be provided with a coating and spacings as
specified in Table 30.3; or
P
b)Shall comply with the requirements for creepages
and clearances as defined by the Standard for
Insulation Coordination Including Clearances and
Creepage Distances for Electrical Equipment, UL
840.
N/A