Energy Guide
Page 43 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
30.9 The spacing requirements in the Standard for
Insulation Coordination Including Clearances and
Creepage Distances for Electrical Equipment, UL
840, shall be amended as follows:
a)For indoor only appliances, the Pollution Degree
shall be 2;
Exception: For air-filtering appliances the Pollution
Degree shall be 3;
b)For indoor/outdoor fans and printed wiring
boards in the airstream of a cooking area, ceiling
insert, or wall-insert fan, the Pollution Degree shall
be 3.
c)Hermetically sealed or encapsulated enclosures,
or conformally-coated printed-wiring boards are
identified as Pollution Degree 1;
P
30.10 The overcurrent protective device mentioned in
31.4.4 or 31.5.4 shall:
a)Not be of the automatic reset type;
b)Be trip-free from the reclosing mechanism when
of the manual reset type; and
c)Not be interchangeable with one of a larger
current rating when it is a renewable device.
P
31 Secondary Circuits N/A
31.1 General N/A