Page 63 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
46.1.9 An observed temperature is to be corrected by
addition [if the ambient temperature is lower than
25° C (77° F)] or subtraction (if the ambient
temperature is higher than 25° C) of the difference
between 25°C and the ambient temperature. If a
corrected temperature exceeds the limit specified
in Table 46.1, at the request of the manufacturer,
the test may be repeated at a temperature closer to
the rated operating ambient.
N/A
46.1.10 For the temperature test, the test voltage for an
appliance is to be as specified in Table 40.1. When
the appliance has a single frequency rating, the
test is to be conducted at that frequency.
P
46.1.11 The appliance is to be operated under each
condition of normal service. For a multispeed
appliance, this includes operation at each speed
and, for a reversible appliance, it includes
operation in each direction of rotation. When a
reversible appliance continues to rotate in the
same direction, but at a slower speed, when the
reversing switch is thrown, the requirement applies
at the lower speed as well as at the normal speed.
The test is to be continued until temperatures have
become constant.
P
46.1.12 A temperature is considered to be constant when
three successive readings taken at intervals of 10
percent of the previously elapsed duration of the
test, but not less than 5 minutes, indicate no further
increase.
P
46.1.13 An appliance employing a general use receptacle
shall be loaded to the marked rating of the
receptacle. The maximum length of the supply cord
is to be used for the Temperature Test.
P