Page 70 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
50.2 For fans rated 12 Amps or less, and that employ
wiring terminals for field wiring connections, the
Locked Rotor Test is to be conducted with supply
wiring sized for the ampacity of the fan. When the
fan is rated more than 12 Amps, the fan is to be
tested with supply wiring sized 125 percent of the
rating of the fan.
P
50.3 The fan is to be installed or placed in its intended
position with the rotor of the fan motor locked and
energized as described in the Locked-Rotor or No-
Load Temperature Test in the Standard for
Impedance Protected Motors, UL 1004-2. The
temperature is to be determined after thermal
equilibrium is attained.
P
50.4 In determining compliance with the requirements
specified in 50.3, motor temperature readings are
to be taken as follows:
P
a)The temperature is to be measured by means of
thermocouples applied directly to the actual
conductor material or the integrally applied
conductor insulation. Thermocouples shall be
placed under the coil wrap, when provided; or
P
b)The temperature is to be measured by use of the
change-in-resistance method.
P
c)In the instance where the motor is totally
enclosed and the temperature can not be
determined by the method in either 50.4 (a) or (b),
the temperature is to be measured by
thermocouples placed on the enclosure.
P
50.5 Under locked-rotor conditions: P
a)The stabilized temperature of an impedance-
protected motor shall not exceed the temperature
obtained when the motor was tested in the open in
accordance with the Locked-Rotor Temperature
Test in the Standard for Overheating Protection for
Motors, UL 2111 or the Locked Rotor or No-
Load Temperature Test in the Standard for
Impedance Protected Motors, UL 1004-2; or
P
b)The motor shall comply with the requirements in
50.6.
P