Page 74 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
56.2 An impeller not required to be guarded is to be
placed in an air-circulating oven maintained at
70°C (158°F) for 7 hours. After removal, it is to be
tested as described in Section 56, Unguarded
Impeller Tests; Section 61, Impact Test on Guards;
and Section 70, Drop Test. As a result of the
testing, the impeller shall not break.
N/A
56.3 A motor-driven impeller not required to be guarded
shall be energy absorbent to the extent that a 3.2
mm (1/8 inch) diameter dry hardwood dowel does
not break when thrust into a rotating blade. The fan
is to be fixed in place and energized so that the
impeller rotates at intended speed. The dowel is to
be supported on a stable, stationary flat surface
perpendicular to the plane of rotation. The surface
is to have a straight edge located approximately
9.5 mm (3/8 inch) from the fan blade. The dowel is
then to be suddenly thrust and retained by hand
along an axis perpendicular to the plane of impeller
rotation into the blade. This procedure is to be
repeated at different points on the impeller (blade
and hub) with the impeller rotating at all intended
speeds and from in front of and behind the impeller
in order to include the most severe condition.
N/A
57 Push Back Relief Test P
57.1 With reference to 15.2.4, a cord-connected fan
shall be tested in accordance with 57.2 without
occurrence of any of the following conditions:
P
a ) Mecharical damage to the supply cord or lead P
b)Exposure of the supply cord or lead to a
temperature higher than that for which it is rated;
P
c)Reduction of spacings (such as to a metal strain-
relief clamp) below the minimum required values;
or
P
d)Damage to internal connections or components. P