Page 76 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
58.3 Where movement of electrical wiring or other
insulated live parts occurs, six representative
samples shall be subjected to this test. Throughout
the test, the appliance shall be continuously
energized at maximum rated input. The movable
member shall be operated so that it will reach the
limits of travel in both directions during each cycle
by either the integral automatic mechanical feature
of the appliance or by a external mechanical
arrangement that operates the movable member.
The cycling rate shall be one of the following:
P
a)tweve cycles perminute P
b)The rate at which the automatic mechanical
feature operates, if the rate is less than 12 cycles
per minute; or
N/A
c)Greater than 12 cycles per minute using the
external mechanical arrangement, if agreeable to
all concerned, or as controlled by the integral
automatic mechanical feature.
N/A
58.4 For an oscillating fan with a tilting head assembly,
two samples are to be oriented in the head fully
forward position, two are to be oriented in the head
straight up position, and two are to be oriented in
the head fully back position.
N/A
59 Tests of Switches and Controls N/A
59.1 Overload N/A
59.1.1 A switch or other device that controls a motor and
that has not been previously investigated for its
suitability of controlling a motor shall perform
acceptably when subjected to an overload test
consisting of 50 cycles of operation, making and
breaking the locked-rotor current of the motor. As a
result of the test, there shall be no electrical or
mechanical breakdown of the device. The fuse in
the grounding connection shall not open.
N/A