Energy Guide
Page 81 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
64.4 The cheesecloth referenced in the Exception to
64.2 is to be bleached, 914.40 mm (36 inches)
wide, 28.22 – 30.24 meters per kilogram (14 – 15
yards per pound), and having what is known to the
trade as a count of 32 × 28 – that is, along the two
directions parallel to the threads, there are 13
threads per centimeter in one direction and 11
threads per centimeter in the other (32 threads per
inch in one direction and 28 threads in the other).
N/A
65 Component Breakdown Test P
65.1 As required by 34.1, a fan shall be subjected to the
Component Breakdown Test as specified in 65.2–
65.12.
P
65.2 With reference to 65.1, a risk of fire or electric
shock is determined to exist when any of the
following occur:
P
a)Glowing, charring, or flaming of the cheesecloth
or tissue paper as specified in 65.6;
b)Opening of the 3 Amp fuse specified in 65.7;
P
65.3 The circuit between any two terminals of a device
is to be opened or shorted. Only one of the simulat
fault conditicns is to be imposed at a time
P
65.4 Each test is to be conducted on a separate sample
unless it is agreeable to those concerned that more
than one test be conducted on the same sample.
P
65.5 A part of the fan that is removed during routine
operation or maintenance is to be omitted when it
results in a more severe test, and the part is not:
P
a)Required for the functioning of the equipment;
and
b)Exposed to view during intended operation.
P
65.6 During these tests, the sample is to be placed on a
softwood surface covered with white tissue paper,
and a single layer of cheesecloth is to be draped
loosely over the entire enclosure.
P
65.7 During each test, exposed dead-metal parts of the
sample are to be connected to earth ground
through a 3 Amp nontime-delay fuse.
P