Page 88 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
72.2 In addition to the requirement in 72.1, a pedestal
intended for ceiling fan mounting that is 1.68 m (66
inches) high or more and that also weighs 11.34 kg
(25 pounds) or more shall not tip over when placed
as intended on a horizontal surface and subjected
to a force of 44.48 N (10 pounds) applied
horizontally at a point farthest from the horizontal
surface up to a maximum of 1.52 m (5 feet).
N/A
72.3 In addition to the requirements in 72.1, a cord
connected freestanding appliance that is 2.1 m (6.9
ft) high or more shall not tip over when placed as
intended on a horizontal surface and subjected to a
force of 20 pounds applied horizontally at a height
of 1.6 m (62 inches).
N/A
72.4 During the tests described in 72.1, 72.2, and 72.3,
the appliance is to be prevented from sliding along
the supporting surface and is to be adjusted and
operated in any intended manner so that it is most
likely to tip over. The test procedure is to include
such items as:
N/A
a)Positioning or removal of casters or feet that do
not require a tool for removal
N/A
b)Operating the fan at maximum speed and then
evaluating it in the "off" position;
N/A
72.5 Testing is to be repeated for all
industrial/commercial air circulator fan head/stand
assembly combinations as described in 80.4.2.
Consideration shall be given to any factor
contributing to product stability including: stand
height, front/back head rotation, side/side head
oscillation, diameter of head assembly, and
size/weight of motor assembly.
N/A
73 Hassock Fan Load Test N/A
73.1 A hassock fan shall sustain a 1779 N (400 pound)
load uniformly distributed over the top of the fan for
1 minute, without breakage or cracking of the
enclosure or guard, after which the probe
illustrated in Figure 9.1 shall not contact a portion
of the impeller that presents a risk of injury to
persons when inserted through any opening in the
guard or enclosure.
N/A
74 Installation Test P
74.1 The appliance shall function in the intended
manner and shall comply with the applicable
requirements in Sections 40 – 65.
P