Energy Guide

Page 90 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
76.9 During the test, the primary switch is to be in the
"on" position, both sides of the primary circuit of the
appliance are to be connected together and to one
terminal of the test equipment, and the second
test- equipment terminal is to be connected to the
accessible dead metal.
P
77 Grounding Continuity Test P
77.1 Each appliance that has a power-supply cord
having a grounding conductor shall be tested to
determine the grounding continuity between the
grounding blade of the attachment plug and the
accessible dead metal parts of the appliance that
are capable of becoming energized.
P
77.2 Only a single test is required to be conducted when
the accessible metal selected is conductively
connected by design to all other accessible metal.
P
77.3 Any indicating device, such as an ohmmeter, a
battery and buzzer combination, or the like, is to be
used to determine compliance with the grounding-
continuity requirement in 77.1.
P
78 Polarization Test N/A
78.1 As a routine production-line test, each appliance
provided with a manually operated, line-
connected, single-pole switch for appliance "on-off"
operation; an Edison-base lampholder or an
Edison- base fuseholder; or a receptacle shall be
tested for electrical continuity between the
grounded supply circuit conductor of the
attachment plug (wide blade of 2-wire plug) and the
part of the appliance that is intended to be
connected to the grounded supply circuit conductor
of the attachment plug. The polarity shall be
determined either visually or through the use of an
electrical test. Equivalently, polarity may be verified
between the ungrounded supply circuit conductor
of the attachment plug and the part of the
appliance that is intended to be connected to the
ungrounded conductor.
N/A
78.2 Any indicating device, such as an ohmmeter, a
battery and buzzer combination, or the like, is to be
used to determine compliance with the requirement
in 78.1.
N/A
79 Details N/A