UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
80.1.3 An appliance that does not start and attain normal
running speed when connected to a circuit
protected by a fuse other than a time-delay fuse as
described in 44.1 shall be plainly marked, "If
connected to a circuit protected by fuses, use time-
delay fuses with this appliance," or with an
equivalent wording.
P
80.1.4 A fan, other than a ceiling insert fan/light
combination, provided with a lampholder for an
incandescent lamp shall be plainly and
permanently marked to indicate the maximum
wattage rating of the lamp to be used in the
lampholder. The marking shall be legible and
located so that it is readily visible after the fan has
been installed.
P
80.1.5 When a manufacturer produces or assembles an
appliance at more than one factory, each finished
appliance shall have a distinctive marking, such as
a code, by which it is identified as the product of a
particular factory.
P
80.1.6 A room-to-room fan shall be marked with the
following or equivalent wording: "Do not mount in a
fire-rated wall."
P
80.1.7 Unless known to be acceptable for the application,
a pressure-sensitive label that is required to be
permanent shall comply with the applicable
requirements in the Standard for Marking and
Labeling Systems, UL 969.
P
80.1.8 An appliance employing a general use receptacle
shall be marked with the rating of the receptacle.
See 21.19 and 21.21.
P
80.1.9 When the fan is marked, or the manufacturer's
instructions indicate, that the fan can be hosed
down with water, the fan shall be subjected to the
test in Section 49, Hosedown Test, and shall
comply with the requirements in 166.2, 166.4.4,
166.5.1, 166.7.1, and 169.1.
P
80.1.11 A fan that complies with Exception No. 6 to 14.1.2
shall be marked with the following or equivalent:
"This fan shall not be installed behind a suspended
floor/ceiling or a structural wall, ceiling, or floor."
P