Energy Guide

Page 93 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
80.1.12 An appliance, as described by rows 1 and 2 of
Table 15.1, provided with a replaceable in-line fuse
or fused attachment plug shall be permanently
marked on the device with the following: “Use Only
With a Fuse Rated Amperes, Volts.” The blanks
shall be filled in with the ampere value consistent
with the rating of the fuse or fuses provided. The
marking shall be visible during fuse replacement.
P
80.2 Motors P
80.2.1 When an appliance employs a single motor as its
only electric-energy-consuming component, the
electrical rating given on the motor nameplate is
not required to be shown elsewhere on the
appliance when the nameplate is readily visible
after the motor has been installed in the appliance.
P
80.2.2 When an appliance employs a dual-voltage motor,
and when the motor nameplate provides the
electrical rating of the appliance as specified in
80.2.1, the appliance shall be additionally marked –
not necessarily in a permanent manner – or other
suitable means shall be provided to indicate the
voltage for which it is connected when shipped
from the factory. When the appliance employs an
attachment plug, instructions shall be provided to
indicate the type of plug that should be used when
the appliance is reconnected for the alternate
voltage.
P
80.2.3 When the motor of a wall-insert fan or ceiling-insert
fan is electrically connected to the fan by an
attachment plug, both the housing and motor-blade
assembly shall be marked with a catalog number, a
model designation, or the equivalent regardless of
whether the fan is completely assembled when
shipped from the factory. Also:
P
a)The motor-blade assembly shall be marked to
positively identify the housing or housings with
which it is suitable; or
b)The housing shall be marked to positively identify
the motor-blade assembly or assemblies with
which it is suitable.
P