UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
80.5.5 A wall-insert fan that is intended to comply with the
requirements in the Exception to 48.1.1 (d) shall be
permanently marked in a location visible during
installation with the following statement or the
equivalent, "For Commercial or Industrial Use."
P
85.5.6 a fan described in a of exception no.2 to9.3.4 shall
be marked install fan at least 1.5 meters(5 Feet)
Above The Floor" or with equivalent wording.
P
80.5.7 A wall or ceiling insert fan or ceiling insert fan/light
combination that is provided with a polymeric
housing shall be marked, "FOR USE IN NON FIRE
RATED INSTALLATIONS ONLY." This marking
shall be permanent in letters not less than 2.4 mm
(3/32 inch) high, shall be located such that it is
visible during installation, and shall be in a
contrasting color from the material to which it is
applied.
P
80.5.8 A wall or ceiling insert fan or ceiling insert fan/light
combination that is provided with a polymeric
housing shall be marked, "FOR USE IN ONE- AND
TWO-FAMILY DWELLINGS ONLY." This marking
shall be permanent in letters not less than 2.4 mm
(3/32 inch) high, shall be located such that it is
visible during installation and inspection of wire
connections, shall be located near the supply
connections, and shall be in a contrasting color
from the material to which it is applied.
P
80.6 Attic-mounted and roof-mounted fans N/A
80.6.1 A fan described in 9.3.6 shall be marked "Install
This Side Of The Fan Facing An Unoccupied
Space" or with equivalent wording.
N/A
80.6.2 A fan described in 9.3.7(b) shall be marked "Attach
Louvers Or Grilles When Installing The Fan" or with
equivalent wording.
N/A
80.7 Wiring P
80.7.1 When the wires in a terminal box or compartment
intended for power-supply connections attain a
temperature of more than 60° C (140°F) during the
Temperature Test, Section 46, the appliance shall
be marked with the following statement, or the
equivalent, at or near the point where supply
connections are made, and located so that it is
readily visible during installation: "For supply
connection, use wires suitable for at least C ( F)."
The temperature value to be used in the preceding
statement shall be in accordance with Table 80.1.
P