Page 97 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
80.7.2 If any point within a terminal box or wiring
compartment of a permanently connected
appliance in which field-installed conductors are
intended to be connected – including such
conductors themselves – attains a temperature
more than 60° C (140° F) during the Temperature
Test, Section 46, the appliance shall be marked in
accordance with 80.7.3. The statement shall be
legible and located so that it is clearly visible during
installation and examination of the supply-wiring
connections.
P
80.7.3 The marking mentioned in 80.7.2 shall be in
accordance with Table 80.1 and the following:
P
When the test was conducted with 14 AWG (2.1
mm2) conductors, the wire size marking is not
required.
P
80.8 Cord tag markings P
80.8.1 The markings specified in this section shall: P
a)Be permanently affixed to an attached power-
supply cord,
P
b)Be located not more than 6 in (152.4 mm) from
the attachment plug,
P
80.8.2 An appliance provided with a replaceable in-line
fuse or fused attachment plug shall be marked
“Always Unplug This Product Before Installing or
Replacing Fuses.”
N/A
80.8.3 A cord-connected appliance, as described in Table
15.1, rows 1 and 2, shall be marked:
N/A
a)“Do not operate any fan with a damaged cord or
plug. Discard fan or return to an authorized service
facility for examination and/or repair.”
b)“Do not run cord under carpeting. Do not cover
cord with throw rugs, runners, or similar coverings.
Do not route cord under furniture or appliances.
Arrange cord away from traffic area and where it
will not be tripped over.”
N/A
81 Cautionary Markings P