Energy Guide
Page 99 of 104 Report No.: HK2107050725-SR
UL 507
Clause Requirement + Test Result - Remark Verdict
TRF No. UL507A
a)"THIS IS A FAN – NOT A TOY!"; and
b)"TO REDUCE THE RISK OF PERSONAL
INJURY AND ELECTRIC SHOCK, IT SHOULD
NOT BE PLAYED WITH OR PLACED WHERE
SMALL CHILDREN CAN REACH IT."
P
81.7 An outdoor location fan employing a receptacle
shall be marked "CAUTION: RISK OF ELECTRIC
SHOCK, Do not use with extension cord near water
or where water may accumulate. Keep fan at least
16 feet from pools and spas. Keep plugs and
receptacles dry."
P
81.8 When required by 21.20, a fan shall be marked to
indicate the type, ampere, and voltage rating of the
replacement fuse. In addition, the portable fan shall
be marked with the word "WARNING" and the
following or equivalent: "For continued protection
against risk of fire, replace only with same type and
rating of fuse." These markings shall be located
adjacent to the fuseholder so as to be visible
during fuse replacement.
P
81.9 A portable fan employing a general use receptacle
that is not subjected to the water spray test (see
48.1.1) shall be marked in a readily visible location
with the word "WARNING" and the following or
equivalent wording: "To reduce the risk of electric
shock, do not expose to water or rain."
P
81.10 A portable fan employing a general use receptacle
that is subjected to the water spray test (see
48.1.1) shall be marked in a location adjacent to
the receptacle "Wet location only when cover
closed."
P
81.11 An industrial air circulator whose surface
temperatures exceed the limits of Table 46.1 (see
footnote l), shall be marked with the word
“CAUTION” and the following or equivalent
wording: "Hot surface . Avoid Cortaca the marking
shall be located or the sulface in question where
visible while operating the actuator
P