Specifications
Inspecting Double Sided Board
To inspect double-sided PCB user must create two Board Setups, one for
topside inspection, one for bottom side inspection. However, it is possible to
have the software to determine which side of the PCB it is going to inspect
and automatically switch the Board Setups for you.
To use the feature user need to:
1. Name the Board Setup for the top side as ****_TOP.xxx, and the bottom
side as ****_BOTTOM.xxx. Where **** is the assembly number for the board.
2. Train a specialised Device and give it the Reference I.D. SIDETAG for each
Board Setup.
The software uses SIDETAG to confirm if the correct Board Setup is loaded. If
not, it will load the complementary Board Setup. Before the inspection begins
try to find the SIDETAG. If SIDETAG is found proceed with the inspection. If
the SIDETAG is not found, load the other Board Setup then proceed with the
inspection.
By using the SIDETAG feature the system will load the Board Setup every
time the side changes. The repeated loading and reloading of the Board
Setups can be time consuming especially in a network environment where the
Board Setup is loaded across the LAN. The Scanspection software is capable
of caching the Board Setups. This feature is disabled by default. To enable
this feature the user may edit the Scanspection.INI file and change
EnableCaching=0 to EnableCaching=1.