Specifications

Train Enable; checking it will enable the auto train feature. In auto-train, the
system automatically searches for the Device in the expected position; if the
Device is found the system adds that Device into the Device list for inspection
and then moves on to the next Device in the CAD data. The training process
continues automatically (unattended), stopping only if the expected Device is
not found or the Device is not in the Device library.
During CAD import, the status line of the main window displays the progress
of the importing process with statements such as "Importing Device 238 of
2034". When all the Device data are imported a dialog will display indicating
the completion of the importing process.
For more information regarding the CAD Interface refer to CAD data
Interface
.
Fine Tuning the Device Parameters
After training all the Devices users should Test The Board several times to
tweak certain Device parameters. To start inspecting the board select File,
Test Board. The software prompts the user to place a board in the machine
for test. Since the board is already in the drawer user should just press OK on
the dialog.
Press Scanner button to re-scan the board and start the inspection. After the
inspection you can Review Failed Devices and make adjustment on the
Device parameters. Repeat the scan-inspect process several times then
switch to a different board of the same assembly number.
After the fine-tuning, save the board train by selecting from the File menu,
Save.
Inspecting the Board
Before inspecting you must load the training (Board Setup file) of the board
from the disk. To load the training select from the File menu, Load Board
Setup, locate the file from the list, then press the Open button.
After the proper Board Setup is loaded, press the Test Board button {bmc
the following dialog will display: