Specifications

System Check up
This section lists a simple test procedure that checks system hardware
functionality and parameter integrity:
1. Start the system from a complete shut down. Observe the stage homing
sequence. For the off-line Scanspection, the Image moves to the right and
the table moves back, then both axes reverse directions and stop near the
centre. For the in-line AOI, the Image transport moves towards the front
right corner, then both axes reverse directions and stop near the centre. If
the homing sequence does not complete correctly, there is a problem with
the motion control system.
2. If the home sequence is correctly completed, enter the Supervisor Mode of
the software, double-click on the video window and observe the Image
movement. The system should centre exactly where the mouse is pointed.
The Video Navigator Scale is Image specific, you need to switch Images
and test the Navigator Scale for each Image.
3. Centre the video cross hair with an image feature on the board. Switch
Images to view the same feature under different magnifications. The cross
hair should stay on the same Device of the feature.