Specifications
Error Messages
This section lists the common error messages:
xxx Device to big (or xxx Lead area to big)
All inspection ROIs (for Devices, lead areas and solder area) must be small
enough to be inspected in one field of view. To allow for search area the ROIs
itself must be smaller than 75% of the field of view. This error message
indicates one of the Device exceed this size limit and cannot be inspected.
Upon seeing this message user must investigate and fixes the problem
Device. Otherwise all Devices appeared after the problem Device in Device
list would not be inspected.
Template Manager, unable to load template
This error message may appear when you try to display the template of a
Device. It indicates that the software is unable to load the template into
memory. To fix the problem, you need to delete or re-train the template
(alternates) that the system is unable to load. If the error message appears
when you try to align the board, the alignment mark templates may be bad.
You may need to re-define the alignment marks.
Grid too dense to display
This error message may appear when you try to switch to a higher
magnification Image. The Map View displays a grid that matches the
magnification; the higher the magnification the denser the grid pattern. If the
Map View window is too small or the board is too large, the grid may be too
dense to be shown. The problem can usually be resolved by enlarging the
Map View Window.