Specifications

Edit Parameter
Launch the Lead Inspector Parameter dialog.
Extended Parameter
This menu item is disabled for algorithm 10. For algorithm 11, the
following dialog display:
Pitch - Separation from one lead to the next can be in
Thou or microns. (typical values, 20 Thou,25
thou,50 Thou)
Regularity Tolerance - High regularity mean the lead to lead
separations are almost the same from one
another. Set this tolerance to detect bend leads or
missing leads. A value of 10% is typical for this
parameter; it can range from 0 to 50%.
Max. Lead Width - Define the maximum apparent width of a lead.
Set this parameter to detect bridging or lead off
pad conditions. A value of 65% is typical for this
parameter; it can range from 50 to 95%.
Threshold Bias - During blob analysis a threshold value is used to
change the grey scale image into a black and