Operating instructions
MAINTENANCE 
31 Dec 13  5-11 
DE-7200VFDCentrifuge 
Cleaning Purge Unit Filter 
Do not use solvents on any part of the filter assembly installed inside the purge unit. To 
clean the filter element, unscrew and remove the filter bowl and then unscrew and 
remove filter element. Clean filter element in soapy water or replace element. 
ROTATING ASSEMBLY MAINTENANCE 
Maintenance of the rotating assembly is limited to removal, cleaning, inspection, and replacement 
of wear inserts. Excessive noise or vibration during centrifuge operation may indicate defective 
main or conveyor bearings. If such conditions are evident, the bearings should be checked for 
high temperature and excessive noise. The rotating assembly must be replaced if defective main 
or conveyor bearings are found, or if internal damage to the rotating assembly is  found or 
suspected. The damaged rotating assembly should be returned to Derrick for overhaul. 
Rotating Assembly Removal 
To remove the rotating assembly, proceed as follows: 
WARNING! TO AVOID SERIOUS PERSONAL INJURY BE SURE EQUIPMENT IS 
LOCKED OUT, TAGGED OUT, DE
-ENERGIZED, AND HAS STOPPED 
ROTATING BEFORE PERFORMING MAINTENANC
E AND/OR ADJUSTMENTS. 
1.  Turn off feed, shut down centrifuge, and lock out and tag out electric power to the centrifuge. 
Allow rotating assembly to coast to a full stop. 
2.  Disconnect feed pipe from feed tube flange. 
3.  Remove screws securing belt guard to case, and lift and remove guard. 
WARNING! WHILE OPENING AND CLOSING THE CENTRIFUGE COVER, 
PERSONNEL MUST ENSURE THAT ALL BODY LIMBS AND ANY OTHER 
ITEMS ARE CLEAR OF THE COVER GAP. TWO OPERATORS MUST BE USED, 
WITH BOTH HANDS ON THE COVER HANDLES AT ALL TIMES. DERRICK 
RECOMMENDS HAVING A HOIST AVAILABLE IF ADDITIONAL ASSISTANCE 
IS DESIRED DURING THE OPENING/CLOSING PROCEDURE. 
4.  Remove screws securing case cover to case, and open case cover  as described at the 
beginning of this section. 
5.  Loosen screws securing torque limiter clutch half to conveyor drive motor shaft (Figure 5-4), 
slide coupling half toward motor until end of motor shaft is visible, and remove spider. 