Operating instructions
MAINTENANCE 
31 Dec 13  5-27 
DE-7200VFDCentrifuge 
ALARM AND FAULT MESSAGES 
Cause  Corrective Action 
F1017 - Bowl VFD Drive OL Alarm, Ref Troubleshooting Section of User Manual 
Feed rate causing overload  Reduce feed rate or reduce bowl speed. 
Bowl drive motor drawing excessive 
current 
Replace motor if defective. 
F1021 - Bowl Motor Thermal Overload Check Bowl Motor Temperature and Thermistor 
Bowl drive motor shut down due to high 
temperature or defective thermistor in 
motor winding 
Check motor temperature. Allow motor to cool, and 
then check for continuity across thermistor leads. If 
open circuit is found, replace motor. 
Bad connection(s)  Check connections at TB2-7 and 8, at 
transmitter/intrinsic barrier, and at conveyor VFD. 
Correct as required. Replace motor if no defects are 
found. 
F2000 - Conveyor Clutch Tripped, Allow Centrifuge to Stop Completely, then Reset 
Clutch 
Conveyor torque has exceeded pre-set 
limit causing clutch to trip 
Allow bowl to come to a complete standstill, and then 
reset clutch as described under Automatic Shutdown 
in Section 4. 
F2001 - Conveyor High Torque Alarm, Reduce Feed Rate 
Conveyor torque exceeds pre-set limit  Reduce feed rate and/or increase differential speed. 
F2002 - Conveyor High Torque Fault and Shutdown, Perform Cleanout and Reduce Feed 
Rate 
Conveyor torque exceeds pre-set limit  After bowl has stopped rotating, perform cleanout 
procedure to remove solids buildup, and re-start 
centrifuge at reduced feed rate and/or higher 
differential speed. 
F2010 - Conveyor VFD Communications Error 
Communication lost between conveyor 
VFD and PLC 
Confirm that green LED next to Ethernet cable on 
Ethernet switch is lighted, indicating that hub is 
functional. 
Check connections between conveyor VFD and 
PLC, and correct any defects. 
Replace conveyor VFD communication module, if no 
other defect is found. 
F2011 - Conveyor VFD Alarm, Ref Troubleshooting Section of User Manual 
Conveyor VFD alarm  Identify alarm from operator control panel. Perform 
indicated corrective action. 