DE-7200VFDCentrifuge 
ALARM AND FAULT MESSAGES 
Cause  Corrective Action 
F7022 - Electrical Enclosure High Temperature Fault and Shutdown 
Control cabinet interior temperature has 
exceeded alarm setpoint 
Check status/operation of air conditioner; repair or 
replace if defective. 
Reduce load by decreasing bowl, conveyor 
differential speed, and/or pump feed rate. 
Interior temperature of control cabinet 
too high, causing shutdown 
Check that air conditioner is operating; repair or 
replace, as indicated. Inspect cabinet interior, and 
remove cause of high temperature, if any. 
Re-start centrifuge after removing cause of high 
temperature. 
F7031 - Enclosure Temperature Sensor Error 
Control cabinet interior temperature 
sensor not functioning 
Check sensor and connection. Correct any wiring 
defects, and replace sensor if defective. 
F8001 - Emergency Stop Switch Activated, Shutdown 
EMERGENCY STOP initiated  Remove cause for emergency stop, pull out 
EMERGENCY STOP, and then re-start centrifuge. 
F8002 - Emergency Stop Switch or Belt Guard Sensor Trip 
EMERGENCY STOP initiated or belt 
guard removed or not secure 
Check and secure belt guard, pull out EMERGENCY 
STOP, and then re-start centrifuge. 
F8003 - High Vibration Fault and Shutdown, Correct Problem and Press Reset Button 
Rotating assembly unbalanced or 
mechanical looseness 
Rotating assembly overloaded or clogged, bearing 
failure, conveyor wear, or loose pillow block bolts 
producing out-of-balance condition. Remove cause 
of excessive vibration and re-start centrifuge. 
F8004 - High Vibration Switch or Bowl Cover Sensor Trip 
Case cover not secure  Check and secure cover, and re-start centrifuge. 
Rotating assembly unbalanced or 
mechanical looseness 
Rotating assembly overloaded or clogged, bearing 
failure, conveyor wear, or loose pillow block bolts 
producing out-of-balance condition. Remove cause 
of excessive vibration and re-start centrifuge. 
F9010 - Control Program Downloaded from Memory Card to Controller 
Re-loading of PLC program from 
memory card completed 
Start centrifuge, and resume operation. 
F9011 - Controller Internal Battery Low, Replace 
PLC battery low  Replace battery. 