Alarm and Fault Messages 
Cause  Corrective Action 
Bowl High Torque Alarm, Reduce Feed Rate 
Bowl torque exceeds pre-set limit  Reduce feed rate. 
Bowl High Torque Fault and Shutdown, Perform Cleanout and Reduce Feed Rate 
Bowl torque exceeds pre-set limit  Following automatic shutdown, perform cleanout 
procedure to remove solids buildup, and re-start 
centrifuge at reduced feed rate. 
Bowl VFD Alarm, Ref Troubleshooting Section of User Manual 
Defective bowl VFD  Press STOP, and cycle power off and then on. If 
alarm does not clear, replace bowl VFD. 
Bowl VFD Communications Error 
Confirm that green LED next to Ethernet cable is 
lighted, indicating that hub is functional. 
Check connections between bowl VFD and PLC, and 
correct any defects. 
Bowl VFD not communicating with PLC 
Replace bowl VFD, if no other defect is found. 
Bowl VFD Drive OL Alarm, Ref Troubleshooting Section of User Manual 
Bowl drive motor drawing excessive 
current 
Replace motor, if defective, or remove other cause of 
excessive current draw. 
Bowl VFD Fault and Shutdown, Ref Troubleshooting Section of User Manual 
VFD fault detected, causing shutdown  Check and replace bowl VFD. 
Bowl VFD Ground Warn Alarm, Ref Troubleshooting Section of User Manual 
Bowl motor has path to ground  Check for ground in bowl motor and connections to 
drive output, and correct defect. 
Bowl VFD In Phase Loss Alarm, Ref Troubleshooting Section of User Manual 
Check wiring between VFD and motor; correct 
defect(s). 
Ground detected between VFD and 
motor in one phase 
Check motor winding for grounded phase; remove 
ground, if any, or replace motor. 
Bowl VFD Power Loss Alarm, Ref Troubleshooting Section of User Manual 
Incoming power loss or low voltage 
supply 