Specifications
Document No. DER05105  TROUBLESHOOTING 
Page 10 of 16  Effective Date  15 Jul 08 
Alarm and Fault Messages 
Cause  Corrective Action 
Pump VFD Drive OL Alarm, Ref Troubleshooting Section of User Manual 
Pump drive motor drawing excessive 
current 
Replace motor, if defective, or remove other cause of 
excessive current draw. 
Pump VFD Fault, Ref Troubleshooting Section of User Manual 
VFD fault detected, causing shutdown  Check and replace pump VFD. 
Pump VFD Ground Warn Alarm, Ref Troubleshooting Section of User Manual 
Pump motor has path to ground  Check pump motor and connections to drive output 
for a grounding; remove ground connection. 
Pump VFD In Phase Loss Alarm, Ref Troubleshooting Section of User Manual 
Check wiring between VFD and motor; correct 
defect(s). 
Check motor winding for grounded phase; remove 
ground, if any, or replace motor. 
Ground detected between VFD and 
pump motor in one phase 
Replace VFD. 
Pump VFD Power Loss Alarm, Ref Troubleshooting Section of User Manual 
Incoming power loss or low voltage 
supply. 
Monitor and correct incoming power defects). 
Pump VFD Undervoltage Alarm, Ref Troubleshooting Section of User Manual 
Incoming power loss or low voltage 
supply 
Monitor and correct incoming power defect(s). 
Solid End Main Bearing High Temperature Alarm 
Insufficient bearing lubrication  Lubricate bearings (refer to DER05023). 
Excess grease  Remove grease fitting, and direct jet of filtered 
compressed air to remove grease. 
Incorrect grease  Lubricate with recommended grease (refer to 
DER05023
). 
Defective bearing  Replace both main bearings (refer to DER05024). 










