INSTALLATION INSTRUCTIONS  Document No. DER03022 
Effective Date  23 Dec 08  Page 11 of 15 
Figure 3022-9 Split Input Power Connections 
Polarity Test 
WARNING! BE CERTAIN THAT MOTORS ROTATE IN CORRECT DIRECTION. 
INCORRECT POLARITY OF CONVEYOR MOTOR WILL CAUSE CONVEYOR 
TO ROTATE AT AN INCORRECT SPEED, WHICH WILL RESULT IN 
PROCESSING PROBLEMS. 
In the following procedure, polarity is critical. Be certain that all motors rotate in the correct 
directions. Simply checking to see if solids are discharged out the solid end DOES NOT ensure 
correct polarity! 
If conveyor motor is wired incorrectly, the conveyor may become plugged or flooded depending 
on the speed settings of the bowl and conveyor. Test for correct polarity of all connections as 
follows: 
1.  Apply power to centrifuge. 
2.  Run bowl at 20 RPM with a conveyor differential speed of 5 RPM. 
3.  Confirm direction of rotation for bowl, conveyor, feed pump, and air conditioner condenser 
motors as follows: 
a.  Bowl - Counterclockwise viewed from fan end 
b.  Conveyor - Clockwise viewed from fan end 
c.  Feed pump - Per manufacturer’s data 
d.  Air conditioner condenser - Clockwise viewed from fan end 
4.  Correct reverse rotation by shutting down power and switching any two of the three power 
leads at the terminal block(s) inside the cabinet (refer to Figure 3022-8 and electrical 
schematic diagram in Section 11. 