Specifications
OPERATING INSTRUCTIONS Document No. DER04098 
Effective Date  06 Jun 08  Page 3 of 19 
Figure 4098-1 Home Screen
Operation 
The Operation screen (Figure 4098-2) is shown when Operation is selected on the Home screen. 
It permits the operator to view and adjust current operating information for the bowl, conveyor, 
and pump. These include set and actual bowl and conveyor RPMs and torque percentages, set 
and actual feed pump flow rate, and bearing temperatures. Adjustments of the conveyor and bowl 
speeds may be performed on this screen using up and down arrows or by entering actual 
numbers on the numeric keypad. In addition, the screen provides options for stopping the 
centrifuge, displaying VFD operation screens, and selecting Status, Clean Out, Faults, Alarms, 
and Home screens. The Bowl, Conveyor, or Pump VFD screens display the current operating 
status of the selected VFD. These screens are described later in this section. 