Specifications

OPERATING INSTRUCTIONS Document No. DER04098
Effective Date 06 Jun 08 Page 7 of 19
Bearing Temperatures
Bearing temperature trends may be viewed in graphical form on the Bearing Temperature screen
(Figure 4098-6). Temperatures are updated in accordance with a pre-set interval, and scroll
buttons are provided to facilitate examination of trends over time. Solid and liquid end
temperatures are displayed at the right side of the screen. The Motor Torque screen is also
accessible from the Bearing Temperature screen. The operator may return to the Operation or
Home screen using the buttons at the lower right of the screen.
Figure 4098-6 Bearing Temperature Screen
Setup
The Setup screen (Figure 4098-7) permits the operator to view feed pump characteristics and set
personal preferences. The feed pump output flow rate and gearbox ratio displayed on the left side
of the Setup screen may not be changed by the operator. However, the operator may adjust the
brightness of the control panel screen and select the temperature units (°C or °F) that will be
shown on other screens.
Options are provided at the bottom of the screen to select the Login, Alarms, Operation, or Home
screens. If Login is selected, prompting will appear to enter a user name and password, which is
available only to authorized personnel. Once entered, the screen permits authorized personnel to
set or change bowl, conveyor, and pump VFD parameters.
The manufacturer’s data plate should include the feed pump gearbox ratio and Output / Rev.
(GPR). This information should be entered by authorized personnel in the fields provided on the
Setup screen.