Specifications
Document No. DER05105  TROUBLESHOOTING 
Page 2 of 16  Effective Date  15 Jul 08 
TROUBLESHOOTING DE-7200 CENTRIFUGE 
Possible Cause  Isolation Procedure & Corrective Action 
Failure Mode 1: Acceptable liquid, Cake Too Thin 
Increase feed rate. 
Increase weir opening (refer to DER04098). 
Insufficient solids in feed 
Reduce differential speed. 
Increase feed rate. 
Check feed pump; if required, check wear and replace worn 
parts. 
Check pump shaft seal, and correct any defects. 
Drop in feed pump rate 
Select RESET on Fault Reset screen to reset flow rate. 
Failure Mode 2: Poor Liquid Quality, Acceptable Cake 
Increase bowl speed. Bowl speed too low 
Reduce feed rate. 
Excessive amount of solids in 
feed 
Reduce quantity of solids in feed or add dilution stream if 
possible. 
Change in feed characteristics  Reduce quantity of solids in feed or generally optimize 
machines settings, i.e. adjust bowl speed, differential speed, 
and weir opening. 
Re-optimize machine settings. 
Reduce feed rate. 
Increase weir opening (refer to DER04098). 
Increase in solids wetness 
Reduce differential speed. 
Conveyor flights worn 
excessively. Inspect flights 
through the solids discharge 
outlets 
Remove and disassemble bowl, and inspect conveyor flights 
(refer to DER05026)
. Repair or replace conveyor, if required. 
Failure Mode 3: Excessive Vibration 
Bowl assembly unbalanced 
due to uneven mechanical 
wear, worn parts, or deformed 
conveyor flights 
Remove and disassemble bowl, and inspect conveyor flights 
(refer to DER05026)
. Repair or replace conveyor, if required. 