User Guide
ISDN Router Manual V.1.1
56
6.3 S Register
Number Meaning Range Unit Description Default
0 Auto answer 0
1 - 255
Time
• manual answer
• Auto answer the incoming data
call after defined counting
0
1 RING count 0 - 255 Time
• stored the RING count
0
2 Escape character 0
0 - 127
ASCII
• disabled
• use the ASCII value as escape
character
43
3 Carriage Return 0 - 127 ASCII
• use the ASCII value as CR
13
4 Line Feed 0 - 127 ASCII
• use the ASCII value as LF
10
5 Back Space 0 - 32 ASCII
• use the ASCII value as BS
8
12 Escape sequence
Prompt time
0
1 - 255
20ms
• do not check guard time
• check guard time
50
25 DTR detection time 0 - 255 0.01sec
• DTR recognized time
20
26 CS delay time 0 - 255 0.01sec
• Delay between lost carrier and
Hang up (RTS to CTS)
1
37 V.110 speed set 5
6
15
17
27
50
• 5 = 1200bps
• 6 = 2400bps
• 15 = 4800bps
• 17 = 9600bps
• 27 = 19200bps
• 50 = 38400bps
50